background image

 

 

- 11 -

   This equipment has been tested and found to comply with the limits for a Class B digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection 
against harmful interference in a residential installation. This equipment generates, uses and can 
radiate radio frequency energy and, if not installed and used in accordance with the instructions, 
may cause harmful interference to radio communications. However, there is no guarantee that 
interference will not occur in a particular installation. 

If this equipment does cause harmful interference to radio or television reception, which can be 
determined by turning the equipment off and on, the user is encouraged to try to correct the 
interference by one or more of the following measures: 

-- Reorient or relocate the receiving antenna. 

-- Increase the separation between the equipment and receiver. 

-- Connect the equipment into an outlet on a circuit different from that to which the receiver is 

connected. 

-- Consult the dealer or an experienced radio/TV technician for help. 

5. Guidance and manufacturer’s delclaration 

 

Guidance and manufacture’s declaration – electromagnetic emission

The 

[EQUIPMENT or SYSTEM] i

s

 intended for use in the electromagnetic environment specified below. The customer of 

the user of the

 

 

[EQUIPMENT or SYSTEM] 

should assure that it is used in such an environment. 

Emission test 

Compliance 

Electromagnetic environment – 

guidance 

RF emissions 
CISPR 11 

Group 1 

The [EQUIPMENT or SYSTEM] use RF 
energy only for its internal function. 
Therefore, its RF emissions are very low 
and are not likely to cause any 
interference in nearby electronic 
equipment. 

RF emission 
CISPR 11 

Class B 

 

Harmonic emissions 
IEC 61000-3-2 

Not applicable 

Voltage fluctuations/ flicker 
emissions 
IEC 61000-3-3 

Not applicable 

 

Guidance and manufacture’s declaration – electromagnetic immunity 

The 

[EQUIPMENT or SYSTEM] 

is intended for use in the electromagnetic environment specified below. The customer 

or the user of 

[EQUIPMENT or SYSTEM] 

should assure that it is used in such an environment. 

Immunity test 

IEC 60601 test 

level 

Compliance 

level 

Electromagnetic 

environment - 

Содержание FT-F11

Страница 1: ...1 Instruction for Use lnfrared Thermometer Contact Type FT F11 BT FT F21 BT FT F12 BT FT F22 BT FT F11 FT F21 FT F12 FT F22 UO8080 UO8080E...

Страница 2: ...Replacement 7 Operation Precautions 8 Precaution for Measuring Temperature 9 Product Specification 10 Common question concerning forehead temperature 2 Product Overview This infrared Thermometer measu...

Страница 3: ...Battery Last Memorized Temperature Display 5 Measuring 1 Ear Measuring Mode Figure 5 1 Suitable for FT F11 FT F11 BT FT F21 FT F21 BT FT F12 FT F12 BT FT F22 FT F22 BT UO8080 UO8080E Turn on the powe...

Страница 4: ...table for FT F21 FT F22 FT F21 BT FT F22 BT UO8080E Turn on the power button key of the IR Thermometer and then all displayed segments appear briefly as like on Figure 5 2A the displayed screen appear...

Страница 5: ...5 seconds until the displayed screen appears or then press the Scan button to switch to ear or forehead measuring mode 5 Memory recall 12 memories recall Press SCAN button key to display M on the disp...

Страница 6: ...lcohol IPA to clean up before or after use Avoid multiple using by different peoples for cross infection Note 1 Any solution dilution and method other than mentioned above might cause reliability prob...

Страница 7: ...attery type and battery life AAA 2pcs Suitable for FT F11 FT F21 FT F11 BT FT F21 BT UO8080 UO8080E 1 PC 2032 button battery Suitable for FT F12 FT F22 FT F12 BT FT F22 BT The typical service life of...

Страница 8: ...e measure voice or other languages voice 2 When the measurement is finished the IR thermometer shall report the measured temperature data The Blue Tooth function model is FT F11 BT FT F12 BT FT F21 BT...

Страница 9: ...he forehead area for temperature given off by the arterial blood supply under the skin without worrying about correct positioning The gentle scan is comfortable and not invasive Measurement method Nor...

Страница 10: ...nt Clinical accuracy characteristics and procedures are available from the manufacturer on request STATEMENTS AND DECLARATIONS 1 MEDICAL ELECTRICAL EQUIPMENT needs special precautions regarding EMC an...

Страница 11: ...the receiver is connected Consult the dealer or an experienced radio TV technician for help 5 Guidance and manufacturer s delclaration Guidance and manufacture s declaration electromagnetic emission T...

Страница 12: ...5 dip in UT for 0 5 cycle 40 UT 60 dip in UT for 5 cycles 70 UT 30 dip in UT for 25 cycles 5 UT 95 dip in UT for 5 sec Not applicable Mains power quality should be that of a typical commercial or hosp...

Страница 13: ...EC 61000 4 3 3 V m 80 MHz to 2 5 GHz 3 V m NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affect...

Страница 14: ...738 1 1 167 1 167 2 333 10 3 689 3 689 7 379 100 11 667 11 667 23 333 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m can be estima...

Страница 15: ...ng instructions IP22 Symbol for the IP classification Symbol for RF transmitters Manufacturer FUDAKANG INDUSTRIAL CO LTD Address No 8 Yinghe Road Yuanjiangyuan Management Zone Changping Town Dongguan...

Отзывы: