For ease of use the Axiom Datalogger has two sensor extensions which can be used with the Radar. 

 

 

 

 

PACKING LIST 
DEFAULT SETTINGS 
SECTION 1: Mounting the Radar 
SECTION 2: Setting Up with FTS Axiom 
Dataloggers 
SECTION 3: Setting Up with Other Data Loggers 
SECTION 4:  Useful SDI-12 Commands 

Use the table to determine which 
sensor extension to use.  If you wish to 
measure parameters using more than 
one measurement command, you must 
use the SDI Generic extension. 

1) Keep a minimum horizontal distance of 200mm (7.87”) to

the nearest solid surface and distance to water surface
should not be less than 0.5 m (1.6 ft).

2) Polarization indicators should be turned to the nearest

vertical surfaces to minimize the effects of false echoes.

3) Orient the radar cone perpendicular to the water’s

surface.

Use the supplied bubble level to confirm.

Polarization indicators 

The Radar Stage Sensor is shipped 
with the following default settings: 
SDI-12 Address 

Units of measurement 

Feet 

Number of samples to 
average 

20 

Power Mode 

High 

Radar Stage Sensor with 
cable 

Mounting Bracket 

Bubble level 

Quick Start Guide 

OPTIONAL PARTS:  

LCD Display, Military Connector 

*For detailed instructions, refer to the Axiom Operator’s
Manual  (700-Axiom-Man) found on the FTS Support site

This Quick Start Guide is meant as a fast reference when setting up your FTS Radar Stage Sensor.  For detailed instructions and 
explanations, refer to the Radar Stage Sensor Operating Manual (700-RSS-Man) and your data logger’s operating instructions.

 

M COMMAND 

RESULTS 

EXTENSION 

aM! 

Average stage, quality metric. 
Averaged over 1-720 samples.  Default = 20 samples. 

Radar or 

SDI Generic 

aM1! 

Instantaneous stage, distance, quality metric, and internal 
temperature (in 

C) 

SDI Generic 

aM2! 

4-20 mA output current (in mA) 

SDI Generic 

aM3! 
aM4! 
aM5! 

Supports NOAA distance calculation. 
Stage, mean distance, standard deviation, number of 
discarded outliers, good 

s

ample count and voltage (in 

V). Averaged over 1-720 samples. 
Sample # Defaults:   aM3! = 360    aM4! = 60     aM5! = 15 