6
- During a long shutdown, disconnect the power supply.
7. CARE AND MAINTENANCE
WARNING: BEFORE ANY OPERATION REMOVE THE ELECTRICAL CORD FROM THE POWER SUPPLY.
Extraction Unit :
- The cleaning of the case is done with soapy water.
- After cleaning, carefully wipe off any moisture.
- Avoid contact between the liquid cleaning product and the electrical parts of the installation.
Filters:
Ref FPP1 (dust removal), FAP1 and FA2 (aerosols).
The clogging of the filters depends on the time of use, the nature and the concentration rate of dust in the
aspirated atmosphere.
In workplaces where these parameters are controlled, the life of a filter can be well determined. Cleaning and
replacement can be planned; this simplifies both routine maintenance and periodic maintenance.
In workplaces where the above mentioned parameters are random, it is recommended to use hoods with filter
loading detection (HI HEPA). This device makes it possible to permanently know the efficiency of the filtering
and to proceed to the replacement as soon as necessary.
In ordinary cases of use, we recommend:
- For routine filter maintenance, cleaning with compressed air at least once a week.
Disassemble the filter element.
Put it horizontally on wedges at the four corners.
Blow with compressed air in the opposite direction of aspiration.
- For periodic maintenance, change the filter at least twice a year.
Ref FCP1:
The use of activated carbons makes it possible to purify the air of impurities and in particular smelly
substances.
The frequency of replacement of activated carbon filters is based on the user's own experience.
This must take into consideration the concentration rate and the nature of the troublesome substances.
By default, it is recommended to change the charcoal filters every 6 to 12 months or more frequently in
intensive use.
7. SPARE PARTS, CONSUMABLES
Spare parts that the user must have
- Fast fuse 1.25 A Quantity: 2
- Filters: According to used model Quantity: 1
- LED bulb G45 4W E27 Quantity: 2
Replacement cord: If the power cable is damaged, it must be replaced by the manufacturer, its after-sales
service or similarly qualified persons in order to avoid danger.