Fume hoods
Soldering - Desoldering
Specialized tools for wiring and tinning
Hand tools, consumables and workshop equipment
–
+33(0)1 40 86 00 09
–
5
Installing the pre-filter on the main filter
This pre-filter is intended to protect the activated carbon filter from any clogging.
- Position the pre-filter on the main filter. Make sure that the longer side of the pre-filter is placed horizontally to
facilitate pinching of the latter from the front.
- Refit the front of the hood.
5. MUFFLER INSTALLATION (OPTIONAL)
- Disassemble the rear grille by removing the 4 screws.
- Insert the angled end of the silencer into the flange and make sure it is securely
fastened. The maintenance is done only by pressure, so you have to fit everything
together.
6. START-UP AND OPERATION
Getting started
- Check that the switches, motor and lighting are in position .0.
- Check that the fan motor speed control knob is in the minimum position: in this position the engine is idling.
- Connect the electrical outlet.
- Switch on the switches, motor and possibly lighting.
- Change the speed of rotation to obtain the necessary suction flow.
It is recommended to favor a reduced speed when using an activated
carbon filter and a maximum speed with a particulate filter.
Stopping the aspiration
- To stop aspiration, set the motor switch to the .0 position.