Section 6
Parameter Settings
62
FT205EV Wind Sensors
– User Manual
6.4.18
MM: Reset or Query the Min/Max Recorded Wind Speed
Command
Parameter
MM
Command
Syntax
SET Sensor:
$<listenerID>,MM<setting>*<checksum><cr><lf>
$aa,MMc*hh<cr><lf>
QUERY Sensor:
$<listenerID>,MM?*<checksum><cr><lf>
$aa,MM?*hh<cr><lf>
Sensor output:
$<talkerID>,MM=<MinSpeed>,<MaxSpeed>*<checksum><cr>
<lf>
$aa,MM=xxx.x,xxx.x*hh<cr><lf>
Parameters
<setting>
R
Resets the min/max readings to their default (<MinSpeed> to 999.9
and <MaxSpeed> to 000.0) until the first reading
<MinSpeed>
000.0 to 999.9
Minimum detected wind speed in current unit (m/s, knots or km/h)
<MaxSpeed>
000.0 to 999.9
Maximum detected wind speed in current unit (m/s, knots or km/h)
Examples
Example 1
Query the min/max wind speed readings
Message
Comment
$01,MM?*//<cr><lf>
Query the min/max readings
$WI,MM=005.1,034.2*22<cr><lf>
Sensor response
Description
Use the MM command to query the minimum and maximum wind speed readings that the
sensor has recorded since it was last switched on. The minimum and maximum readings are
set to their default values when an MMR, an RS or a DF set command is executed.