6.4.16 HT.1: Query Heater Settings
Command
Parameter
HT (Heater Query)
Command
Syntax
QUERY Sensor:
$<listenerID>,HT?*<checksum><cr><lf>
$aa,HT?*hh<cr><lf>
Sensor output:
$<talkerID>,HT=<tsp>,<%>,<temp>*<checksum><cr><lf>
$aa,HT=xx,xx,
xx*hh<cr><lf>
Parameters
<tsp>
99
Heater disabled (factory default setting
– cannot be modified)
<%> This feature is not applicable to the FT205EV product
<temp>
-99 to +99
Read only parameter that returns the current internal temperature of
.
the sensor, In
⁰
C, in the range 00 to ±99
⁰
C
Examples
Example 1
Query the Heater settings.
Message Comment
$01,HT?*//<cr><lf>
Query heater setting
$WI,HT=99,00,
+24
*3B<cr><lf>
Sensor Response (+24°C)
Description
The HT query command requests the status of the internal heater circuit. Since no heater
functionality is included in the FT205EV product, it can only provide details of the internal
temperature.
In comparison to other sensors in the FT product range, users should be aware the SET
heater command is disabled on the FT205EV product. Only the QUERY command is
available with limited functionality.
Contact FT Technologies for further information about the HT command and the heater
performance of various FT wind sensors.
Ensure the user application and system does not require heater operation and that the
connected system can operate without the legacy functionality of other sensors in the FT
range.