ARC (Alarm Receiving Centre)
The ARC settings determine which messages are to be sent to the monitoring centre/control room.
Protocol
The ARC protocol must be set to GSM CID in order for the alarms to be sent to the control room. If
ARC is set to disabled, no alarms will be sent to the control room.
Alarms
The option must be SET if alarm messages (such as burglaries and panic messages) are to be sent to
the control room.
Tampers
The option must be SET if tamper messages (such as PIR tampers, door contact tampers or alarm
panel tampers) are to be sent to the control room. The default is SET.
available outputs on the panel (see Section 2 - Wiring the alarm panel). Wireless outputs work
with the wireless bi-directional gate module (digital I/O).
W Serial (Wireless Serial Number)
The serial number can be typed into the serial number field or entered automatically by
activating the tamper button on the wireless device. Refer to the in-box leaflet for the wireless
sensor. Alternatively, the serial number for the wireless device can be entered on the keypad. The
serial number for the wireless device is printed on the sticker on the wireless device. To type in
the wireless serial number, type in the number written next to the ID on the label. See Appendix
A - Hex Entry Mode.
Communications
Choose the Communications Menu
from the Configuration Menu
Latching
The output is either ON or OFF. If this option is SET, the output is latching.
Inverted
The state of the output is inverted (ON -> OFF and OFF -> ON). For example, if an output is
turned on when the panel is armed and the inverted state is selected, the output will then be
turned off when the panel is armed.
Pulse
When the output is activated it will turn on for a period of time and then turn off again. For
example, a gate controller will use a pulsed output. When this option is set, the output will
pulse for one second when it is activated
W Type (Wiring Type)
The output can either be wired (outputs 1 and 2 only) or wireless. Wired outputs use the two
22 Rhino 232 Installation Manual
|