5.0
Operating Procedure
A.
Test run: start and stop
1. Connect power, ground cable, and check power supply.
2. Maintain oil level by keeping it visible in the sight glass by the oil fill port on the side of the airend.
3.
If the initial start of the unit will be 6 months or longer after delivery, add 0.5
quarts of CurtisLubePlus FSC- 8000
lubricant through air inlet valve and rotate air end
manually to prevent compressor damage due to lack of oil.
4. Check cooling system
5.
Check Motor Rotation:
Press the “Start” button and immediately push the “Emergency Stop”
button. Verify the rotation of the motor coupling against arrow on airend. This will require help from
an additional person. Switch any 2 of the 3 power cables if direction is not correct.
6. Press “START” button to restart the compressor.
7. Observe any warnings on controller screen.
8. Time delay will be activated after pressing the “STOP” button; the motor will stop automatically
after 10-15 seconds.
9. Compressed air will be released immediately after pressing the “OFF” button.
B. Inspection before start
In order to protect the compressor and increase operation efficiency it is necessary to inspect the system
prior to operation.
1.
Open both ball valves below the oil tank to drain any water. Condensed water will cause
bearing damage and reduce the lifespan of the lubricant.
2. Check oil level:
Do not use other lubricant than CurtisLubePlus FSC- 8000
for warranty purposes.
Make sure that the pressure is released before refilling.
Warning: Opening the oil fill cap while under pressure may cause injury.
3. Inspect the oil level 10 minutes after unit stops. The Oil level could read lower during operation.
C. During operation
1.
Stop the compressor if any abnormal noise or vibration is observed.
2. Do not loosen any screws or open any control valve during operation.
Warning: Doing so may cause injury.
3.
Make sure any condensed water is released from the after cooler (SEG-10/15 models only). Moisture
is not allowed in the system.
4.
Record discharge pressure, discharge temperature, oil level and inspect gauge periodically during
operation for future reference.
Содержание SEG-10
Страница 11: ...CAP881 11 ...
Страница 12: ...CAP881 12 ...
Страница 13: ...CAP881 ...
Страница 14: ...CAP881 14 ...
Страница 15: ...CAP881 ...
Страница 16: ...CAP881 16 ...
Страница 17: ...CAP881 17 ...
Страница 18: ...CAP881 18 ...
Страница 20: ...CAP881 20 ...
Страница 24: ...CAP881 24 SEG 10 15 System Flow Diagram ...
Страница 32: ...CAP881 32 6 0 Maintenance 6 1 Maintenance Intervals ...
Страница 44: ...CAP881 44 NOTES ...