FSA GT7-2K Скачать руководство пользователя страница 5

2.  Before the lamp is installed, the chamber and surrounding plumbing must be free from water or 

leaks. 

3.  Insert the UV lamp into the quartz thimble through the open end. Leave the 4 pins of the lamp 

exposed to allow connection to the ballast. 

a.  For vertical installation, you will need to connect the power supply first before lowering the 

tube into the chamber. Do NOT drop the tube as this will cause the thimble to crack. 

4.  Firmly holding the white cap of the UV lamp, and the Black connection of the Ballast, push the 

power supply connection onto the UV lamp pins, there is a long and short side of the pins so they 
will only go into the power supply 1 way. Ensure that this is connected firmly so there is a good 
connection. 

a.  At this point the lamp should be tested briefly to ensure it is in working order and the 

connection is sound. 

b.  Keep your hands clear of the system and turn on the power for 5 seconds to allow the lamp 

to fire. Do not look directly at the lamp without eye protection.  

c.  Confirm that the lamp lights up correctly, and the ballast is showing a green light to signify 

that the lamp is running correctly.

 

 

d.  Turn off the power.

 

 

5.  Slide the lamp the remaining way into the chamber, pushing the rubber sleeve over the knurled nut. 

NOTE: The rubber sleeve is not a waterproof seal and is not designed to seal the water in the 
chamber, it is only to hold the lamp in place and protect from slight splashing water – this 
does not make the chamber IP rated as waterproof.

 

6.  Connect the earth wire to the lug on the bottom of the UV chamber as shown above. 
7.  Plug the ballast into a certified single socket surge protector, then into a 240V 10A GPO 
8.  Turn on the power supply to start the lamp. 

a.  If there is a green light, everything is running correctly 
b.  If there is a red flashing light with an audible alarm sounding, the ballast is indicating that 

there is a problem with the lamp. This may be due to a faulty lamp, or the connection was 
not sound during installation. Or there may possibly be a water leak that is shorting out the 
lamp. 

c.  Fix the issue if possible or contact the supplier for further information. 

Maintenance 

I. Replacement Parts 

Ultraviolet Lamps have an effective lifespan of 9000 Hours (12 Months). They are designed for continuous 
run, not for intermittent operation. 

Lamp Replacement | Every 12 Months

 

GT7-2K-Lamp  

 

14W Replacement UV Lamp Suit GT7-2K 

GT7-4K-Lamp  

 

20W Replacement UV Lamp Suit GT7-4K 

GT7-8K-Lamp  

 

40W Replacement UV Lamp Suit GT7-8K 

Quartz Thimble Replacement | Every 1 – 2 years depending on water quality 

GT7-2K-Thimble 

 

331mm x 23mm OD Single Open-End Thimble Suit GT7-2K 

GT7-4K-Thimble 

 

490mm x 23mm OD Single Open-End Thimble Suit GT7-4K 

GT7-8K-Thimble 

 

895mm x 24.5mm OD Single Open-End Thimble Suit GT7-8K 

Содержание GT7-2K

Страница 1: ...ase Open 2 V Space Requirements 3 VI What is Ultraviolet Sanitation 3 VII Example Applications 3 Installation Introduction 3 I Site Preparation 3 II Mounting 4 III Installing Connections 4 IV Filter P...

Страница 2: ...he unit from power surges Danger Dangerous electrical voltage is present inside the power supply box chamber These instructions must be followed closely tom prevent serious personal injury Ensure Eye...

Страница 3: ...il it is finally eradicated Ultraviolet filtration is a chemical free solution to water sanitation creating no by products in the water Ultraviolet systems are rated based on a dosage level of radiati...

Страница 4: ...knurled nut goes at the open end of the thimble Loosely screw on both nuts until you feel resistance Then simultaneously tighten both nuts by hand until it is firmly hand tight NOTE Firmly hand tighte...

Страница 5: ...not a waterproof seal and is not designed to seal the water in the chamber it is only to hold the lamp in place and protect from slight splashing water this does not make the chamber IP rated as water...

Страница 6: ...tem 1 Particularly on the smaller model GT7 2K if there are periods of low water usage or the water is allowed to stand for long periods of time the water may be prone to heating up and may be either...

Страница 7: ...failed This can also occur from shorts and water ingress Check for signs of a short around the lamp connection end The ballast will need to be replaced The UV lamp may also have blown at the same time...

Страница 8: ...by a qualified plumber The consumer is responsible for keeping record and proof of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations i...

Страница 9: ...ty is valid only if the following conditions are met The System was installed by a licenced plumber proof of installation required in the form of a receipt or invoice for works The system was maintain...