.                                  value will alternate  
Light 1: 

 

Light is blinking when filter 1 is due for replacement 

Light 2: 

 

Light is blinking when filter 2 is due for replacement 

Light 3: 

 

Light is blinking when filter 3 is due for replacement 

Light 4: 

 

Light is blinking when 4x RO membranes require replacement 

Light 5: 

 

Light is blinking when Post (Final) filter requires replacement 

SET Button:   

Used to modify settings on Micro-Computer ,Change filter times and TDS Setting 

Zero Button:   

For resetting filter change reminder & adjusting filter change times and TDS Setting 

TDS Display:   

Shows TDS of pure filtered water, shows Replacement time and TDS setting 

“ 

 “ Light: 

 

Light is on when TDS is below set value – System operating correctly. 

“ ! “ Light: 

 

Light is on when TDS is above set value – Change Membranes 

(b) Functionality Instructions

 

1.  After completed installation, the LED will show “FSH” and the system will flush the membranes for 

15 sec. After flushing the system will start to produce RO water, the micro controller will start to 
display a TDS value after 4 minutes  

2.  When the Storage tank is full OR the system becomes a closed circuit (by turning off the outlet line 

using a tap), the TDS will stop detecting. The “FSH” will display on screen, then the system will 
trigger an automatic flush lasting for 15 seconds. During this flush cycle, you must maintain inlet 
(source) water so the system has a supply of water for flushing. After flushing “FUL” will display on 
screen for 10 sec 

3.  When the Storage tank is empty OR the System becomes an open circuit (by opening the outlet 

valve or tap) the high-pressure switch will be delayed for 25 seconds before starting the flush 
process, then will begin to produce pure water. The high-pressure switch will be switched on and off 
which will cause the electromagnetic valve to open and shut (this will make an audible noise). 

4.  When the source (influent) water is stopped, the low-pressure switch will delay for 10 seconds 

before triggering the system to shut down. This delay prevents over pressurisation when the flow 
rate is insufficient. To prevent such things from happening, the low-pressure switch will turn on and 
off triggering the solenoid valve to do the same (this will make an audible noise). During this delay 
period, if the influent water is turned back on, it will cancel the shut off process. When the influent 
water has stopped, this will also cease the TDS from being detected.  

(c) Preview Default Settings:

 

1.  First, press and hold the Setup button for 2 seconds, this will display the first setting mode. The LED 

will show 103 and light 1 will begin to blink. Factory settings are 103 which indicate that the first filter 
replacement is sent to alarm every 3 months. The first digit signifies the filter number and the last 2 
digits signify the month. 

2.  Press the Setup button to bring up the filter 2 timer. It will show 206 and light 2 will blink. The factory 

setting for 206 means the 2

nd

 filter replacement reminder alarm is set to 6 months  

3.  Press the Setup button to bring up the filter 3 time. It will show 306 and light 3 will blink. The factory 

setting for 306 means the 3

rd

 filter replacement reminder alarm is set to 6 months  

4.  Press the Setup button to bring up the filter 4 time. The LED display will show 075 and light 4 will 

begin to blink. 075 indicates the TDS limit of the RO membranes. This means when the TDS is 
above 75 ppm, the replacement change light will blink and the membranes will require replacement. 

5.  Press the Setup button to bring up the filter 5 time (post filter). It will show 512 and light 5 will blink. 

The factory setting for 512 means the 5

th

 filter replacement reminder alarm is set to 12 months  

6.  If you want to return to original settings, hold the Setup button again for 2 seconds and wait for the 

“Beep, Beep”. 

7.  If you need to change multiple settings, do them all in sequence then press and hold the Setup 

Button for 2 seconds and wait for the “Beep, Beep” to complete all the settings. 

(d) Changing computer Settings: 

For applications where the influent water is municipal and free from most sediments, you can extend the 
replacement warning for filter 1 to 6 months. To do this, Press and hold “SET” key for 2 seconds, then 
proceed by entering the 1

st

 setting mode. The LED display will show 103 and filter 1 light will begin to flash, 

Press “ZERO” key then the number on the LED display will count up from 103 -> 104 ->105 and finally 106. 

Содержание GT1-98

Страница 1: ...I Installation Mounting 4 III Installation Free Standing 4 IV Installing Connections Quick Connect 5 V Filter Protection 5 VI Drain Waste 5 VII Cartridge Installation 5 a Pre Filters 5 b Membranes 6 c...

Страница 2: ...re You Purchase Open The system requires specific working conditions to be met before installation some general guidelines are listed below If these conditions are not met the system may not be suitab...

Страница 3: ...nerally required town water to be filtered through the RO membranes to reduce or remove the dissolved solids from the water These systems are favoured to produce this water in house rather than purcha...

Страница 4: ...mmon use of a calcite filter is in the following orientation RO System Tank Calcite Filter Standard Filtration Big Blue UV House De Ionising Demineralising DI units are common as they are now required...

Страница 5: ...sure the increase water discharge is within specification for your septic system In some cases where the feed water quality is good the discharge water may be suitable for utility use and watering not...

Страница 6: ...is removed and there should be a open end of tubing at the top of the system which is the outlet d De Ionising Post Filters For DI Cannister filters temporarily run a small length of tubing form the s...

Страница 7: ...ssure switch will turn on and off triggering the solenoid valve to do the same this will make an audible noise During this delay period if the influent water is turned back on it will cancel the shut...

Страница 8: ...this point the working pressure gauge will remain at 0 until the water reaches the membranes Once the water reaches the membranes the drain line should begin to sputter and produce water it is normal...

Страница 9: ...Municipal water supplied the pre filters should be changed every 45 000L 720 Hours constant Run Time OR 6 Months whichever occurs first Post Carbon Filter This filter should be changed every 5 000L or...

Страница 10: ...tomer support Unit is not producing any water 1 Water supply is off or disconnected 2 Filter Blockage 3 Insufficient incoming water pressure 4 Water Quality 5 Outlet tubing float is closed or blocked...

Страница 11: ...the water to vent the pH 3 Bacterial contamination is highly unlikely but not impossible If there is a strong foul smell or organic taste to the water it is possible that there is some form of contami...

Страница 12: ...of of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations including the use of replacement filters fittings and components supplied by FS...

Страница 13: ...f the system is installed on an open circuit a plumber may not be required in this case the system must be installed in accordance with the user manual and determined to be correctly installed by FSA...

Отзывы: