Depth: 29cm 
Width: 45 cm 
Height: 85cm 

If the system is to be enclosed in a cover, allow adequate ventilation around the pumps & power supplies to 
prevent overheating. 

IV. Before You Begin Installation 

These RO units come pre-assembled on the bracket will all connections in place. These units are wet 
tested for leaking before they are sent to ensure there are no leaks due to assembly. Due to transit, fittings 
and other components may become loosened or damaged. 

Ensure the system is inspected for 

damages prior to employing a plumber for installation. 

V. What is Reverse Osmosis 

The Reverse Osmosis Membrane is the workhorse of any RO system. It is constructed from a wrapped 
semi-permeable membrane material that uses pressure to separate impurities such as ions, minerals and 
other larger molecules from the water, carrying them to waste. 

*Reverse Osmosis membranes do not have a L Capacity for filter replacements due to the variables that 
can make the filter life vary significantly. This is mostly due to the water quality. The most accurate way to 
test an RO membrane for effectiveness is to use a TDS Meter. TDS meters measure the total dissolved 
solids in ppm in the water. To test your membrane, get a baseline reading out of your tap (unfiltered water) 
and then compare that to a reading directly off the membrane (disconnect the tube before it goes into the 
post filter cartridge). You can expect to get a difference of approx. 90-98% between the readings which 
indicate that the membrane is functioning correctly. If this % is beginning to drop below 90% it suggests 
that the RO membrane requires replacement. 

VI. Example Applications 

The LSRO commercial systems are fairly versatile and are suitable for a range of different uses. There are 
3 main applications for these systems; 

Manufacturing Water, Bore Water TDS Reduction & Medical 

Sterilisation

 

Manufacturing Water

 generally required town water to be filtered through the RO membranes to reduce or 

remove the dissolved solids from the water. These systems are favoured to produce this water ‘in house’ 
rather than purchasing commercial quantities of de-mineralised or distilled water which can be costly. Most 
mains water applications are straight forward however some water supplies contain higher levels of 
hardness which may require treating before the system. 

Bore Water

 filtration is used when the water meets specific conditions where an RO unit will be suitable to 

remove elevated salt levels in the water (generally TDS <2,000 mg/L*). Where salt levels exceed the 
ADWG and need to be removed to supply potable water to a household. 

Medical Sterilisation

; it is now a requirement for dental & medical industries to utilise reverse o 

de-i UV sanitised water for use in equipment sterilisation. These systems can feed 0 TDS water 
into Autoclave systems for the compliant sterilisation of medical equipment. (UV system not included).  

VII. Installation with other Systems 

It is common for these systems to be supplied with other additional filtration systems for different 
applications. The most common of these would be a Water Softener. Below are some example scenarios. 
NOTE: These are just guidelines and may be different depending on the requirements of the job. Check 
with the client or supplier as to which type of installation order is required for not standard installations. 

UV Systems

: There are 2 ways to utilise UV with an RO system 

1. UV can be used to sanitise the incoming feed water into an RO system. This is generally required on 
scenarios where there are high or potential bacterial loading levels in the feed water. Bacteria can severely 
affect an RO system performance and may cause Bio-Fouling. UV is used to eliminate or significantly 
reduce bacteria. 

2. Post storage sanitation is required if your RO water is filtering into a storage tank. This is the same 
principle as treating rain water from a tank into your house. While RO water is generally free from 

Содержание GT1-98

Страница 1: ...I Installation Mounting 4 III Installation Free Standing 4 IV Installing Connections Quick Connect 5 V Filter Protection 5 VI Drain Waste 5 VII Cartridge Installation 5 a Pre Filters 5 b Membranes 6 c...

Страница 2: ...re You Purchase Open The system requires specific working conditions to be met before installation some general guidelines are listed below If these conditions are not met the system may not be suitab...

Страница 3: ...nerally required town water to be filtered through the RO membranes to reduce or remove the dissolved solids from the water These systems are favoured to produce this water in house rather than purcha...

Страница 4: ...mmon use of a calcite filter is in the following orientation RO System Tank Calcite Filter Standard Filtration Big Blue UV House De Ionising Demineralising DI units are common as they are now required...

Страница 5: ...sure the increase water discharge is within specification for your septic system In some cases where the feed water quality is good the discharge water may be suitable for utility use and watering not...

Страница 6: ...is removed and there should be a open end of tubing at the top of the system which is the outlet d De Ionising Post Filters For DI Cannister filters temporarily run a small length of tubing form the s...

Страница 7: ...ssure switch will turn on and off triggering the solenoid valve to do the same this will make an audible noise During this delay period if the influent water is turned back on it will cancel the shut...

Страница 8: ...this point the working pressure gauge will remain at 0 until the water reaches the membranes Once the water reaches the membranes the drain line should begin to sputter and produce water it is normal...

Страница 9: ...Municipal water supplied the pre filters should be changed every 45 000L 720 Hours constant Run Time OR 6 Months whichever occurs first Post Carbon Filter This filter should be changed every 5 000L or...

Страница 10: ...tomer support Unit is not producing any water 1 Water supply is off or disconnected 2 Filter Blockage 3 Insufficient incoming water pressure 4 Water Quality 5 Outlet tubing float is closed or blocked...

Страница 11: ...the water to vent the pH 3 Bacterial contamination is highly unlikely but not impossible If there is a strong foul smell or organic taste to the water it is possible that there is some form of contami...

Страница 12: ...of of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations including the use of replacement filters fittings and components supplied by FS...

Страница 13: ...f the system is installed on an open circuit a plumber may not be required in this case the system must be installed in accordance with the user manual and determined to be correctly installed by FSA...