Commercial Reverse
Osmosis Water Filter System
125L/Hr – GT1-98
Contents
Technical Overview ...................................................................................................................................... 2
I. Important Notes ..................................................................................................................................... 2
II. Before You Purchase/Open .................................................................................................................. 2
III. Space Requirements ............................................................................................................................ 2
IV. Before You Begin Installation ............................................................................................................... 3
V. What is Reverse Osmosis ..................................................................................................................... 3
VI. Example Applications .......................................................................................................................... 3
VII. Installation with other Systems ............................................................................................................ 3
Installation Introduction ................................................................................................................................. 4
I. Site Preparation ..................................................................................................................................... 4
II. Installation – Mounting .......................................................................................................................... 4
III. Installation – Free-Standing ................................................................................................................. 4
IV. Installing Connections – Quick Connect ............................................................................................... 5
V. Filter Protection .................................................................................................................................... 5
VI. Drain/Waste ......................................................................................................................................... 5
VII. Cartridge Installation ........................................................................................................................... 5
(a) Pre-Filters ........................................................................................................................................ 5
(b) Membranes ...................................................................................................................................... 6
(c) Post Filters ....................................................................................................................................... 6
(d) De Ionising Post Filters .................................................................................................................... 6
Connecting the System................................................................................................................................. 6
I. Tubing .................................................................................................................................................... 6
II. Power.................................................................................................................................................... 6
Start Up & Operation .................................................................................................................................... 6
I. Micro-Computer Instructions .................................................................................................................. 6
(b) Functionality Instructions .................................................................................................................. 7
(c) Preview Default Settings: ................................................................................................................. 7
(d) Changing computer Settings: ........................................................................................................... 7
(e) Automatic Reminder Instructions: ..................................................................................................... 8
II. Commissioning ..................................................................................................................................... 8
III. General Operation ............................................................................................................................ 8
IV. Automation .......................................................................................................................................... 9
Maintenance ................................................................................................................................................. 9
Страница 1: ...I Installation Mounting 4 III Installation Free Standing 4 IV Installing Connections Quick Connect 5 V Filter Protection 5 VI Drain Waste 5 VII Cartridge Installation 5 a Pre Filters 5 b Membranes 6 c...
Страница 2: ...re You Purchase Open The system requires specific working conditions to be met before installation some general guidelines are listed below If these conditions are not met the system may not be suitab...
Страница 3: ...nerally required town water to be filtered through the RO membranes to reduce or remove the dissolved solids from the water These systems are favoured to produce this water in house rather than purcha...
Страница 4: ...mmon use of a calcite filter is in the following orientation RO System Tank Calcite Filter Standard Filtration Big Blue UV House De Ionising Demineralising DI units are common as they are now required...
Страница 5: ...sure the increase water discharge is within specification for your septic system In some cases where the feed water quality is good the discharge water may be suitable for utility use and watering not...
Страница 6: ...is removed and there should be a open end of tubing at the top of the system which is the outlet d De Ionising Post Filters For DI Cannister filters temporarily run a small length of tubing form the s...
Страница 7: ...ssure switch will turn on and off triggering the solenoid valve to do the same this will make an audible noise During this delay period if the influent water is turned back on it will cancel the shut...
Страница 8: ...this point the working pressure gauge will remain at 0 until the water reaches the membranes Once the water reaches the membranes the drain line should begin to sputter and produce water it is normal...
Страница 9: ...Municipal water supplied the pre filters should be changed every 45 000L 720 Hours constant Run Time OR 6 Months whichever occurs first Post Carbon Filter This filter should be changed every 5 000L or...
Страница 10: ...tomer support Unit is not producing any water 1 Water supply is off or disconnected 2 Filter Blockage 3 Insufficient incoming water pressure 4 Water Quality 5 Outlet tubing float is closed or blocked...
Страница 11: ...the water to vent the pH 3 Bacterial contamination is highly unlikely but not impossible If there is a strong foul smell or organic taste to the water it is possible that there is some form of contami...
Страница 12: ...of of installation in the form of an invoice and or receipt Filter systems must be maintained as per FSA recommendations including the use of replacement filters fittings and components supplied by FS...
Страница 13: ...f the system is installed on an open circuit a plumber may not be required in this case the system must be installed in accordance with the user manual and determined to be correctly installed by FSA...