I. Important Notes 

For correct operation of this appliance, it is essential to observe the manufacturer’s instructions. 

Installation must be carried out by a qualified plumber or authorised technician to comply with Australian 
Plumbing Codes. This RO system is certified to WaterMark Standards AS/NZS 3497 Under the Certificate 
number 23247. WaterMark certification is the level of certification required by law for a licensed plumber in 
Australia to install a water filter system. 

You will find most answers to your queries can be found in this instruction manual – please 
thoroughly read through this manual from front to back including the troubleshooting page before

 

contacting customer support. 

II. Before You Purchase/Open 

The system requires specific working conditions to be met before installation. If these conditions are not 
met, the system may not be suitable for the application and may not function as specified. 

Feed Water 
Conditions 

Min 

Max 

Inlet Pressure 

350 kPa 

700 kPa 

Temperature 

4.5°C 

38°C 

pH Level 

11 

TDS 

0 mg/L 

2,000 mg/L 

Iron 

0 mg/L 

0.3 mg/L 

Manganese 

0 mg/L 

0.1 mg/L 

Hardness 

0 mg/L 

200 mg/L

 

 

III. Space Requirements 

System Dimensions (5 Stage) 

Height: 43cm 
Width: 37cm 
Depth: 21cm 

Storage Tank Dimensions (12L) 

Height (With Stand): 42cm 
Height (No Stand): 38.5cm 
Width: 27cm 

IV. Before You Begin Installation 

All components that come pre-assembled will need to be thoroughly checked before installation. Due to 
transit, fittings and other components may be loosened or unseated – ensure fittings, tubing and filters are 
inspected before continuing. 

V. What is Reverse Osmosis 

Reverse osmosis is a process that uses a semi permeable, spiral wound membrane to separate and 
remove dissolved solids, organics, pyrogens, colloids and bacteria from water. The Feed water is delivered 
under pressure at 50psi or above through the permeator where the water permeates the minute pores of 
the membrane and is split into purified water which is delivered to the tap, and concentrate (reject) water 
which is sent to waste. Reverse Osmosis is capable of removing 85 – 99.99% of a large range of solids 
from water (depending on the solid) along with Organics and Bacteria. 

Содержание GT1-26-5

Страница 1: ...ion 3 II Drain Clamp 3 III Drilling Faucet Hole Stainless Steel Sink 3 IV Mounting the Faucet 4 4 V Storage Tank Assembly 4 VI Assembling the System Photos Below 5 Connecting the RO System 6 I Tubing...

Страница 2: ...sure 350 kPa 700 kPa Temperature 4 5 C 38 C pH Level 2 11 TDS 0 mg L 2 000 mg L Iron 0 mg L 0 3 mg L Manganese 0 mg L 0 1 mg L Hardness 0 mg L 200 mg L III Space Requirements System Dimensions 5 Stage...

Страница 3: ...Water Adaptor in between DO NOT apply thread tape to these connections as they are designed to use the washers only Thread tape is only required on the male thread of the FWA if it is not installing...

Страница 4: ...und a stem gasket to seal the water the compression ring then prevents the tubing from being removed In this instance thread the Compression nut over the tubing followed by the cone washer Then firmly...

Страница 5: ...ternal cartridges maintain minimal contact with the surface of the carbon filter handle by the end caps only to avoid contamination 5 Screw up the housings while they are in a vertical position to ens...

Страница 6: ...eaches the membrane 5 When the water first comes out of the tap it will be grey and discoloured this is normal as the carbon fines are flushed out of the dry filters NOTE Air bubbles are also common i...

Страница 7: ...l tank of water Maintenance I Replacement Parts Filtration tubing should be replaced periodically about every 3 5 years There is no specific time Fittings should be replaced every 3 5 years due to wea...

Страница 8: ...ally this noise is caused when the installer fails to install the membrane into the housing which causes certain parts of the system to malfunction Check the box and packaging for any leftover or spar...

Страница 9: ...our units and conduct research If you feel that there is an issue with your pH please contact us Strange taste to the water New System 1 Alkaline Filter 2 Residue 3 Contamination 1 If you are using an...

Страница 10: ...Check the feed water conditions and replace the filters if they are passed the recommended change times Water constantly running to waste 1 Air Lock 2 Faulty Shut Off Valve 3 Still Filling 4 Low Press...

Страница 11: ...acts as a cushion which compresses when system pressure suddenly increases or surges as a result of hydraulic shock The water hammer arrestor is installed either at your washing machine or your dishwa...

Страница 12: ...stems must be installed by a qualified plumber The consumer is responsible for keeping record and proof of installation in the form of an invoice and or receipt Filter systems must be maintained as pe...

Страница 13: ...to terms and conditions outlined below This extended warranty covers the below parts of the system GT8 0S Twin O Ring Housings GT8 31 Reverse Osmosis Housing GT35 12 NPT Stainless Steel Centre Joiner...