CHAPTER 5:  PREVENTATIVE MAINTENANCE 

 

 

5-3 

5.4  Periodic/Annual (cont.) 

 

Built-in Filtration (cont.): 

 

 

Check filtration system integrity as follows:  

 

 

With the filter pan empty, place each oil return handle, one at a time, in the ON position.  Verify 
that the pump activates and that bubbles appear in the cooking oil/shortening of the associated 
frypot. 

 

 

Close all oil return valves (i.e., place all oil return handles in the OFF position).  Verify proper 
functioning of each oil return valve by activating the filter pump using the lever on one of the oil 
return handle microswitches.  No air bubbles should be visible in any frypot.  

 

 

Verify that the filter pan is properly prepared for filtering, then drain a frypot of oil heated to 
350°F (177°C) into the filter pan and close the frypot drain valve. Place the oil return handle in 
the ON position. Allow all cooking oil/shortening to return to the frypot (indicated by bubbles in 
the cooking oil/shortening). Return the oil return handle to the OFF position. The frypot should 
refill in no more than 2 minutes and 30 seconds. 

 

 

To ensure good fryer health and a safe environment, the fryer should be checked and adjusted 
periodically by qualified service personnel as part of a regular kitchen maintenance program.

 

 
 

5.5  Stainless Steel Care 

 

 WARNING

 

DO NOT let water splash into the tank of hot oil.  It will splatter and can cause severe 

burns. 

 
All stainless steel fryer cabinet parts should be wiped regularly with hot, soapy water during the day, 
and with a liquid cleanser designed for stainless steel at the end of each day. 

 

A.

 

Do not use steel wool, abrasive cloths, cleansers or powders. 

 

B.

 

Do not use a metal knife, spatula or any other metal tool to scrape stainless steel!  Scratches 
are almost impossible to remove. 

 

C.

 

If it is necessary to scrape the stainless steel to remove any encrusted materials, soak the area 
first to soften the deposit, then use a wood or nylon scraper only. 

 

Содержание YSCF14G Series

Страница 1: ...ood Equipment Service Association recommend using CFESA Certified Technicians www frymaster com 24 Hour Service Hotline 1 800 551 8633 YSCF14G Series Gas Fryers Installation Operation Manual YSCF14G S...

Страница 2: ...evice may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation While this device is a verified Class A devic...

Страница 3: ...CYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN OR ANY OF ITS AUTHORIZED SERVICE CENTERS AND OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION THIS WARRANTY WILL BE VOID FURTHER FR...

Страница 4: ...YSCF14G INSTALLATION OPERATION MANUAL TABLE OF CONTENTS Page 1 Installation 1 1 2 Fryer Operations 2 1 3 Filtration Instructions 3 1 4 Computer Operation 4 1 5 Preventive Maintenance 5 1...

Страница 5: ...ck disconnect devices if used shall likewise comply with national and local codes DANGER The fryer MUST be connected to the gas supply specified on the rating and serial number plate located on the ba...

Страница 6: ...l pipe joints with a sealant resistive to LP gas When using thread compound on gas piping use very small amounts and only on male threads Use a pipe thread compound that is not affected by the chemica...

Страница 7: ...o other way G Only qualified service personnel should make adjustments to the regulators H Orifices The fryer can be configured to operate on any available gas The correct safety control valve appropr...

Страница 8: ...r in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition DANGER This fryer is equipped with a three prong grounding plug for protection against electrical shock an...

Страница 9: ...e the drain valve completely and remove the crumb screen covering the heating tubes Ensure the screws holding the thermostat and high limit control sensing bulbs into the frypot are tight WARNING Do n...

Страница 10: ...t in a suitable container or cut it into small pieces and pack it below the heat tubes between the tubes and on top of the tubes leaving no air spaces around the tubes Do not disturb or bend the sensi...

Страница 11: ...s WARNING When operating the filtration system never leave the filter unattended The action of the oil moving through the hose lines could jolt a flexible return hose where applicable out of the filte...

Страница 12: ...systems 3 2 Filtration Preparation On initial installation and before each use remove all loose parts from the filter wash the filter pan and all accessories in hot soapy water and dry thoroughly 3 2...

Страница 13: ...h the notch toward the pick up tube 4 Place the crumb screen in the filter pan Allow the crumb screen to rest on the top edges of the hold down ring 5 Place filter pan cover onto the filter pan assemb...

Страница 14: ...procedures and may not conform to on site management operational procedures 3 3 1 General Overview The filter pump is turned on only after the oil is brought to operating temperature and drained into...

Страница 15: ...ess Steel Crumb Scoop for removing large debris from shortening oil prior to filtering Note Always wear oil resistant insulated gloves and or protective gear when working with hot oil 3 4 Operating th...

Страница 16: ...g burner heat to an empty frypot will severely damage the frypot and void all applicable warranties DANGER NEVER attempt to clear a clogged drain valve from the front of the valve Hot oil or shortenin...

Страница 17: ...l Use extreme caution as shortening oil is at or near operating temperature 350 F 177 C 3 Remove the support grid from the frypot using the clean out rod or tongs Stir the oil with the L shaped Teflon...

Страница 18: ...left to right to start the filter pump 3 4 2 Filter Operation cont 4 After ensuring the filter pan is correctly positioned under the drain tube and the pan are properly connected drain the frypot into...

Страница 19: ...s arrow Probe location will vary according to fryer system 7 Allow the oil to circulate for approximately 30 minutes process known as polishing to remove suspended particles 8 After the filter cycle i...

Страница 20: ...close the oil return valve and deactivate the filter pump 10 If the oil level is low add oil until the level is at the top OIL LEVEL line Remember the oil is at operating temperature 11 Replace the fr...

Страница 21: ...nd of frying operations each day Some food particles can spontaneously combust if left soaking in certain shortening material WARNING Do not bang fry baskets or other utensils on the fryer s joiner st...

Страница 22: ...tely after pressing a lane key to launch a cook cycle for the desired product The keys are also used to enter names of products Each button when repeatedly pressed accesses multiple letters or symbols...

Страница 23: ...ance 5 2 Daily WARNING Use a commercial grade cleaner formulated to effectively clean and sanitize food contact surfaces Read the directions and precautionary statements for use Particular attention m...

Страница 24: ...resent and properly installed Verify that component box components i e computer controller transformers relays interface boards etc are in good condition and free from oil migration build up and other...

Страница 25: ...ing oil shortening to return to the frypot indicated by bubbles in the cooking oil shortening Return the oil return handle to the OFF position The frypot should refill in no more than 2 minutes and 30...

Страница 26: ...g Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 JULY 09 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 81...

Отзывы: