CHAPTER 5:  PREVENTATIVE MAINTENANCE 

 

 

5-2 

5.4  Periodic/Annual 

 

This appliance should be inspected and adjusted periodically by qualified service personnel as 
part of a regular kitchen maintenance program. 

 

Frymaster recommends that this appliance be inspected at least annually by a Factory 
Authorized Service Technician as follows: 
 

 

Inspect the cabinet inside and out, front and rear for excessive oil build-up and/or oil migration. 

 

Verify that the flue opening is not obstructed by debris or accumulations of solidified oil or 
shortening. 

 

Verify that burners and associated components (i.e. gas valves, pilot assemblies, ignitors, etc.) 
are in good condition and functioning properly.  Inspect all gas connections for leaks and verify 
that all connections are properly tightened. 

 

Verify that the burner manifold pressure is in accordance with that specified on the appliance’s 
rating plate. 

 

Verify that the temperature and high-limit probes are properly connected, tightened and 
functioning properly, and that mounting hardware and probe guard are present and properly 
installed. 

 

Verify that component box components (i.e. computer/controller, transformers, relays, interface 
boards, etc.) are in good condition and free from oil migration build-up and other debris.  Inspect 
the component box wiring and verify that connections are tight and that wiring is in good 
condition. 

 

Verify that all safety features (i.e. drain safety switches, reset switches, etc.) are present and 
functioning properly. 

 

Verify that the frypot/cookpot is in good condition and free of leaks and that the frypot/cookpot 
insulation is in serviceable condition.  Verify that the frypot tube diffusers are present and in 
good condition (i.e. no visible deterioration or damage). 

 

Verify that wiring harnesses and connections are tight and in good condition. 

 

Built-in Filtration: 

 

 

Inspect all oil-return and drain lines for leaks and verify that all connections are tight. 

 

 

Inspect the filter pan for leaks and cleanliness.  Empty crumbs in the crumb basket into a 
fireproof container. Clean basket daily.  Advice owner/operator not to allow crumbs to 
accumulate in basket.  Insist they clean the basket daily. 

 

 

Verify that all O-rings and seals (including those on quick-disconnect fittings) are present and in 
good condition.  Replace O-rings and seals if worn or damaged. 

 
 
 

Содержание YSCF14G Series

Страница 1: ...ood Equipment Service Association recommend using CFESA Certified Technicians www frymaster com 24 Hour Service Hotline 1 800 551 8633 YSCF14G Series Gas Fryers Installation Operation Manual YSCF14G S...

Страница 2: ...evice may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation While this device is a verified Class A devic...

Страница 3: ...CYCLED PART PURCHASED DIRECTLY FROM FRYMASTER DEAN OR ANY OF ITS AUTHORIZED SERVICE CENTERS AND OR THE PART BEING USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION THIS WARRANTY WILL BE VOID FURTHER FR...

Страница 4: ...YSCF14G INSTALLATION OPERATION MANUAL TABLE OF CONTENTS Page 1 Installation 1 1 2 Fryer Operations 2 1 3 Filtration Instructions 3 1 4 Computer Operation 4 1 5 Preventive Maintenance 5 1...

Страница 5: ...ck disconnect devices if used shall likewise comply with national and local codes DANGER The fryer MUST be connected to the gas supply specified on the rating and serial number plate located on the ba...

Страница 6: ...l pipe joints with a sealant resistive to LP gas When using thread compound on gas piping use very small amounts and only on male threads Use a pipe thread compound that is not affected by the chemica...

Страница 7: ...o other way G Only qualified service personnel should make adjustments to the regulators H Orifices The fryer can be configured to operate on any available gas The correct safety control valve appropr...

Страница 8: ...r in the absence of local codes with the National Electrical Code ANSI NFPA 70 latest edition DANGER This fryer is equipped with a three prong grounding plug for protection against electrical shock an...

Страница 9: ...e the drain valve completely and remove the crumb screen covering the heating tubes Ensure the screws holding the thermostat and high limit control sensing bulbs into the frypot are tight WARNING Do n...

Страница 10: ...t in a suitable container or cut it into small pieces and pack it below the heat tubes between the tubes and on top of the tubes leaving no air spaces around the tubes Do not disturb or bend the sensi...

Страница 11: ...s WARNING When operating the filtration system never leave the filter unattended The action of the oil moving through the hose lines could jolt a flexible return hose where applicable out of the filte...

Страница 12: ...systems 3 2 Filtration Preparation On initial installation and before each use remove all loose parts from the filter wash the filter pan and all accessories in hot soapy water and dry thoroughly 3 2...

Страница 13: ...h the notch toward the pick up tube 4 Place the crumb screen in the filter pan Allow the crumb screen to rest on the top edges of the hold down ring 5 Place filter pan cover onto the filter pan assemb...

Страница 14: ...procedures and may not conform to on site management operational procedures 3 3 1 General Overview The filter pump is turned on only after the oil is brought to operating temperature and drained into...

Страница 15: ...ess Steel Crumb Scoop for removing large debris from shortening oil prior to filtering Note Always wear oil resistant insulated gloves and or protective gear when working with hot oil 3 4 Operating th...

Страница 16: ...g burner heat to an empty frypot will severely damage the frypot and void all applicable warranties DANGER NEVER attempt to clear a clogged drain valve from the front of the valve Hot oil or shortenin...

Страница 17: ...l Use extreme caution as shortening oil is at or near operating temperature 350 F 177 C 3 Remove the support grid from the frypot using the clean out rod or tongs Stir the oil with the L shaped Teflon...

Страница 18: ...left to right to start the filter pump 3 4 2 Filter Operation cont 4 After ensuring the filter pan is correctly positioned under the drain tube and the pan are properly connected drain the frypot into...

Страница 19: ...s arrow Probe location will vary according to fryer system 7 Allow the oil to circulate for approximately 30 minutes process known as polishing to remove suspended particles 8 After the filter cycle i...

Страница 20: ...close the oil return valve and deactivate the filter pump 10 If the oil level is low add oil until the level is at the top OIL LEVEL line Remember the oil is at operating temperature 11 Replace the fr...

Страница 21: ...nd of frying operations each day Some food particles can spontaneously combust if left soaking in certain shortening material WARNING Do not bang fry baskets or other utensils on the fryer s joiner st...

Страница 22: ...tely after pressing a lane key to launch a cook cycle for the desired product The keys are also used to enter names of products Each button when repeatedly pressed accesses multiple letters or symbols...

Страница 23: ...ance 5 2 Daily WARNING Use a commercial grade cleaner formulated to effectively clean and sanitize food contact surfaces Read the directions and precautionary statements for use Particular attention m...

Страница 24: ...resent and properly installed Verify that component box components i e computer controller transformers relays interface boards etc are in good condition and free from oil migration build up and other...

Страница 25: ...ing oil shortening to return to the frypot indicated by bubbles in the cooking oil shortening Return the oil return handle to the OFF position The frypot should refill in no more than 2 minutes and 30...

Страница 26: ...g Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 JULY 09 PRINTED IN THE UNITED STATES SERVICE HOTLINE 1 800 551 8633 81...