![Frymaster LOV BIGL30 Series Скачать руководство пользователя страница 36](http://html1.mh-extra.com/html/frymaster/lov-bigl30-series/lov-bigl30-series_installation-operation-and-maintenance-manual_2340547036.webp)
5-6
Figure 4
The air/gas mixture is properly adjusted when the burner manifold pressure is in accordance with the
applicable table on page 2-7 and the burners display a bright orange-red glow. If a blue flame is
observed, or if there are dark spots on a burner face, the air/gas mixture requires adjustment.
On the side of the blower housing opposite the motor is a plate with one or two locking nuts. Loo-
sen the nut(s) enough to allow the plate to be moved, then adjust the position of the plate to open or
close the air intake opening until a bright orange-red glow is obtained. Carefully hold the plate in
position and tighten the locking nut(s).
TYPICAL BLOWER ASSEMBLY
SOME CE BLOWER ASSEMBLIES
MAY BE CONFIGURED THIS WAY
5.6
SEMI-ANNUAL CHECKS AND SERVICE
5.6.1 Clean Gas Valve Vent Tube
NOTE: This procedure is not required for fryers configured for export to CE
countries
.
1.
Set the fryer power switch and the gas valve to the OFF position.
2.
Carefully unscrew the vent tube from the gas valve.
NOTE:
The vent tube may be straightened
for ease in removal.
Right
Viewing
Port
Left Viewing
Port is Behind
Motor
(NOTE: Blower
shield omitted
for clarity.)
Содержание LOV BIGL30 Series