![Frymaster LOV BIGL30 Series Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/frymaster/lov-bigl30-series/lov-bigl30-series_installation-operation-and-maintenance-manual_2340547034.webp)
5-4
6.4
MONTHLY CHECKS AND SERVICE
5.4.1 Check the Manual LOV™ M3000 Set Point Accuracy
(This check applies only to units equipped with a Manual LOV™ M3000.)
1. Insert a good-grade thermometer or pyrometer probe into the oil, with the end touching the fryer
temperature-sensing probe.
2. When the controller display shows a series of dashes “----” or a product name (indicating that the
frypot contents are within the cooking range), press the
switch once to display the
temperature and setpoint of the cooking oil as sensed by the temperature probe.
3. Press
the switch twice to display the set point. The setpoint is the temperature with a dot after
it.
4. Note the temperature on the thermometer or pyrometer. All three readings should be within
± 5ºF (2ºC) of each other. If not, contact a Factory Authorized Servicer for assistance.
5.5
QUARTERLY CHECKS AND SERVICE
5.5.1 Clean Combustion Air Blower Assembly
1.
Disconnect the blower wiring harness and remove the four blower mounting nuts (see Figure 1
below). In some positions, the module may need to be removed prior to removing the blower.
Figure 1
2.
Remove the three fasteners that secure the blower motor assembly to the blower housing, and
separate the two components (see Figure 2 on the following page).
Wiring connection
Blower
assembly
mounting nuts