1-20
Problem Probable
Causes Corrective
Action
3000 display is in
wrong temperature
scale (Fahrenheit or
Celsius).
Incorrect display option programmed.
Fryers using the 3000 controller can
toggle between F° to C° by pressing the
button until Main Menu changing to
Product setup is displayed. Press
to
scroll to Tech Mode and press
. Enter
1658. Press the scan button. The
controller displays
OFF
. Turn the
controller on to check temperature. If
the desired scale is not displayed,
repeat.
Fryers using the CM3.5 should refer to
the separate Fryer Controllers User’s
Manual.
3000 displays
SERVICE
REQUIRED
followed
by the error
.
An error has occurred.
Press YES to silence alarm. The error
is displayed three times. See list of
issues in section 1.12.4. Fix issue. The
controller displays
SYSTEM
ERROR FIXED? YES/NO.
Press YES. Pressing NO will allow
the fryer to cook but the error will be
redisplayed every 15 minutes.
Controller displays
CHANGE FILTER
PAPER?
Daily filter paper change prompt has
occurred.
Press
(YES), follow prompts and
change the filter paper.
3000 display shows
hot-hi-1
.
Frypot temperature is more than 410ºF
(210ºC) or, in CE countries, 395ºF
(202ºC).
This in an indication of a malfunction in
the temperature control circuitry,
including a failure of the high-limit
thermostat.
3000 display shows
HI-LIMIT.
Controller in high-limit test mode.
This is displayed only during a test of
the high-limit circuit and indicates that
the high-limit has opened properly.
3000 display shows
temperature
alternating
with
MLT-CYCL
.
Frypot temperature is below 180°F (82°C).
This display is normal when the fryer is
first turned on while in the melt cycle
mode. To bypass the melt cycle press
and hold the EXIT COOL button for
three seconds.
EXIT MELT
alternating with
YES/NO
is displayed.
Press the YES button.
3000 display shows
low temp
alternating with
temperature.
Frypot temperature is between 180°F
(82°C) and 315°F (157°C).
This display is normal when the fryer is
heating and out of melt cycle until the
temperature reaches
±
2° of setpoint.
Controller
displays
lo
or
LOw temp
.
Frypot temperature has dropped more than
21ºF (12ºC) for CM3.5 or 40°F (17°C) for
3000 controllers below setpoint in idle
mode or 45°F (25°C) in cook mode.
This display is normal for a short while
if a large batch of frozen product is
added to the frypot or if the fryer is not
heating properly.
3000 display shows
low temp
,
heating
indicator cycles on and
off normally but fryer
does not heat.
A.
Failed controller.
B.
Damaged controller wiring harness.
A. Replace controller.
B. Replace controller wiring harness.