![Frymaster FPEL114C Скачать руководство пользователя страница 42](http://html1.mh-extra.com/html/frymaster/fpel114c/fpel114c_service-and-parts-manual_2340500042.webp)
2-9
2.5.1 Component Boxes cont.
ITEM PART
#
COMPONENT
1
106-5592
Box Assembly, Component
2
200-3300
Bracket, Component Box Strain Relief
√
3
807-0012
Relay, Filter 18A, 1/3HP 24VAC
√
4
807-0670
Relay, Filter DPDT 20A 24VAC
√
5
807-4770
Relay, 240V DPDT 20A
√
807-4346
Relay, 120V DPDT 20A
(used in Canadian models only)
6
807-0037
Terminal, ¼-inch Push-on
7
807-0121
Bushing, Heyco Plastic AB-625-500
8
807-0922
Holder, Buss Fuse HPS Screw Type
√
9
807-2278
Fuse, 20 Amp
10
810-2446
Plug, Button .50 Heyco Double “D”
√
11
807-4036
Switch, Power
807-3575
Plug, Carling Switch Hole
(used on some models without a switch)
12
807-1947
Plug, Button .875 Dome
13
807-1321
Holder, AGC Panel Mount ¼” Fuse
(Some models use item 10 here.)
14
807-1597
Fuse, 3 AMP Slow-Blow
15
106-5750
Harness Assembly, RE FV Control
16
106-5751
Harness Assembly, RE DV Control
√
17
807-0855
Transformer, 100-120V 12V 20VA
√
18
807-0800
Transformer, 100-120V 24V 50VA Filter
√
19
807-0680
Transformer, 208-240V 24V 20VA Filter
√
20
807-2191
Transformer, 208-240V 12V 30VA
√
21
807-0979
Transformer, 208-240V 12V 43VA
√
22
807-2180
Transformer, 100-120V 50VA Filter
√
23
812-2126
Transformer, 208-250V 24V 75VA w/o Fuse
(Used in DV component boxes)
√
24
807-4967
Transformer, 100-120V 24V 75VA
(Used in DV component boxes)
√
25
807-4968
Transformer, 208-250V 24V 75VA
(Used in DV component boxes)
√
26
826-2260
Interface Board Standard Full or Dual Vat
(includes sound harness)
*
106-6501
Fallback Controller Assembly
*
807-4403
Speaker, 4-Watt SMT
27
809-0349
Spacer, 4mm X 6mm Aluminum
28
816-0217
Paper, Insulating Terminal Block
29
810-0045
Bushing, .875 Diameter 11/16”
30
806-9495SP
Terminal Block
√
31
807-4346
Relay, DPDT 20A 120V
(used for control power reset in right hand boxes only
in domestic and Canadian units)
√
807-4770
Relay, DPDT 20A 240V
(used for control power reset in right hand boxes only
in international units; some international units have one located in each control
box)
32
807-2659
Switch, Momentary (
used to reset control power; located in box over JIB only.
)
33 230-5038
Guard,
Switch
√
34
807-1174
Fuse, 250V 3 AMP Slow-Blow
35
810-2445
Plug, Button .625 Heyco Double “D”
36
220-8467
Guard Finger OCF with JIB
(use 220-5038 for OCF without JIB)
√
37
807-4678
Switch, Momentary JIB Reset
*
826-2249
RE Hood/Ansul Interlock Kit (includes terminal block, wires and connectors)
* Not illustrated.
√
Recommended parts.
Содержание FPEL114C
Страница 35: ...2 2 2 2 Basket Lift Assembly and Associated Parts...
Страница 41: ...2 8 2 5 Electronics and Wiring Components 2 5 1 Component Boxes...
Страница 46: ...2 13 2 5 5 Heating Element Assemblies and Hardware NOTE These elements apply only to FPEL series fryers...