1-55
1.18.9 OQS (Oil Quality Sensor) Troubleshooting
Problem
Probable Causes
Corrective Action
No TPM results
displayed.
A.
Temperature too low or too high.
B.
Loose pre-screen filter.
C.
Missing, cracked or worn O-rings.
D.
Dirty filter paper.
E.
TPM too high.
F.
Error code.
Check the following items A-E and
perform another OQS filter.
A.
Ensure the vat is at setpoint
temperature.
B.
Inspect the pre-screen filter and
ensure it is screwed in tightly.
C.
Inspect the O-rings on the filter
pan and ensure they are both
present and that they are not
missing, cracked or worn. If so
replace them.
D.
Ensure the filter paper is not
clogged and clean filter paper is
used. Did the vat refill the first
time for the previous filter? If not
change the filter paper.
E.
Dispose of the oil.
F.
Check error log for any OQS
errors E70-76. See explanation and
solution in section 1.18.4.
Controller does not
display OQS software
version.
A.
Loose or damaged harness.
B.
Defective OQS sensor.
A.
Check harnesses between
controllers and OQS sensor are
secure. Ensure 5VDC is present
on pins 4 & 6 of J6 and J7 of the
controller. Check for loose or
broken pins/wires. If the problem
persists, cycle power on the fryer.
B.
Defective OQS sensor.
Содержание FilterQuick FQG30
Страница 8: ...1 3 ...
Страница 41: ...1 36 1 16 2 Bulk Wiring ...
Страница 56: ...1 51 1 18 6 Clogged Drain Failed Oil Sensor Error Flowchart ...
Страница 57: ...1 52 1 18 7 Menu Trees 1 18 7 1 FilterQuick Controller Setup Menu Tree ...
Страница 58: ...1 53 1 18 7 2 FilterQuick Filter and Info Mode Menu Tree ...
Страница 62: ...1 57 1 20 Principal Wiring Connections ...
Страница 63: ...1 58 1 21 Wiring Diagrams 1 21 1 Main FQG 230 430 120V CE Export ...
Страница 64: ...1 59 1 21 2 Main FQG 230 430 Australia ...
Страница 65: ...1 60 1 21 3 Main FQG 230 430 120V CE Export with Solid Shortening ...
Страница 66: ...1 61 1 21 4 Main FQG 230 430 Australia with Solid Shortening ...
Страница 67: ...1 62 1 21 5 Main FQG 330 530 120V CE Export ...
Страница 68: ...1 63 1 21 6 Main FQG 330 530 Australia ...
Страница 69: ...1 64 1 21 7 Main FQG 330 530 120V CE Export with Solid Shortening ...
Страница 70: ...1 65 1 21 8 Main FQG 330 530 Australia with Solid Shortening ...
Страница 71: ...1 66 1 21 9 Transformer Filter Box 430 530 ...
Страница 72: ...1 67 1 22 Simplified Wiring Diagrams 1 22 1 FilterQuick FQG30 Series Simplified Wiring with Push Pull Handles ...
Страница 73: ...1 68 1 22 2 FilterQuick FQG30 Series Simplified Wiring with Push Buttons ...
Страница 74: ...1 69 1 22 3 FilterQuick FQG30 Series Data Network Flowchart ...
Страница 76: ...1 71 1 24 Shortening Melting Unit Wiring Diagram ...
Страница 77: ...1 72 1 25 Modular Basket Lift Wiring Diagram 100 120V ...
Страница 78: ...1 73 1 26 Modular Basket Lift Wiring Diagram 208 250V ...
Страница 79: ...THIS PAGE INTENTIONALLY LEFT BLANK ...