1-30
Buttons and LED’s
Manual
– This button is used to toggle between auto and manual filtration mode. A corresponding LED is lit
when in Manual mode. When pressed, a message will be sent to all vats, indicating the mode has changed.
The following buttons are inoperable in auto mode:
Select
- This button is used to scroll through available vats, choosing one to be manually filtered.
Drain
– This button is used to open and close the drain on the vat indicated on the display. It’s embedded
LED indicates the following activity:
Blink:
Actuator is moving or awaiting a response from the AIF board, or an error conditions exits.
Constant Illumination:
Drain open.
No Illumination:
Drain closed.
Return
– This button is used to open and close the return valve on the vat indicated on the display. When
pressed and held, it also turns on and off the pump. It’s embedded LED indicates the following activity:
Blink:
Actuator is moving or awaiting a response from the AIF board, or an error condition exists.
Constant Illumination:
Return valve open.
No Illumination:
Return valve closed.
The pump is turned off first before closing the return valve or the valve will open first before turning on the
pump.
1.15.1 Manually Draining, Refilling or Filtering using the MIB board
Press the manual/auto switch to set to manual. The LED on the
manual key will illuminate and a vat number is displayed (see
Figure 8).
Figure 8
Press the vat selector switch to change vats (see Figure 9).
Figure 9
Pressing the drain or pressing the return switch illuminates and
activates the drain or return valve for the vat indicated. Pressing
and holding the return switch while the return is open activates
the filter motor and pump (see Figure 10).
Pressing the manual/auto switch will return to automatic mode.
Figure 10
Содержание FilterQuick FQG30
Страница 8: ...1 3 ...
Страница 41: ...1 36 1 16 2 Bulk Wiring ...
Страница 56: ...1 51 1 18 6 Clogged Drain Failed Oil Sensor Error Flowchart ...
Страница 57: ...1 52 1 18 7 Menu Trees 1 18 7 1 FilterQuick Controller Setup Menu Tree ...
Страница 58: ...1 53 1 18 7 2 FilterQuick Filter and Info Mode Menu Tree ...
Страница 62: ...1 57 1 20 Principal Wiring Connections ...
Страница 63: ...1 58 1 21 Wiring Diagrams 1 21 1 Main FQG 230 430 120V CE Export ...
Страница 64: ...1 59 1 21 2 Main FQG 230 430 Australia ...
Страница 65: ...1 60 1 21 3 Main FQG 230 430 120V CE Export with Solid Shortening ...
Страница 66: ...1 61 1 21 4 Main FQG 230 430 Australia with Solid Shortening ...
Страница 67: ...1 62 1 21 5 Main FQG 330 530 120V CE Export ...
Страница 68: ...1 63 1 21 6 Main FQG 330 530 Australia ...
Страница 69: ...1 64 1 21 7 Main FQG 330 530 120V CE Export with Solid Shortening ...
Страница 70: ...1 65 1 21 8 Main FQG 330 530 Australia with Solid Shortening ...
Страница 71: ...1 66 1 21 9 Transformer Filter Box 430 530 ...
Страница 72: ...1 67 1 22 Simplified Wiring Diagrams 1 22 1 FilterQuick FQG30 Series Simplified Wiring with Push Pull Handles ...
Страница 73: ...1 68 1 22 2 FilterQuick FQG30 Series Simplified Wiring with Push Buttons ...
Страница 74: ...1 69 1 22 3 FilterQuick FQG30 Series Data Network Flowchart ...
Страница 76: ...1 71 1 24 Shortening Melting Unit Wiring Diagram ...
Страница 77: ...1 72 1 25 Modular Basket Lift Wiring Diagram 100 120V ...
Страница 78: ...1 73 1 26 Modular Basket Lift Wiring Diagram 208 250V ...
Страница 79: ...THIS PAGE INTENTIONALLY LEFT BLANK ...