NOTE: Outlet gas pressure must be adjusted strictly within the above requirements 5 to 10 minutes after the appliance is
operating.
1.4
Connection to the Gas Supply Line
NOTE:
The gas supply (service) line must be the same size or greater
than the fryer inlet line. This appliance is equipped with a ½-inch (15-
mm) inlet. The gas supply line must be sized to accommodate all gas-
fired equipment connected to the line. Consult the local gas company
or supplier, or your local contractor for minimum supply line
requirements.
NOTE:
If quick-disconnect supply lines or flex lines are used,
increase supply line size to ¾-inch (22-mm) or larger.
DANGER
A manual shut-off valve must be installed in the gas supply (service) line upstream of this appliance and in
a position where it can be reached quickly in the event of an emergency.
DANGER
The fryer must be connected to the gas supply specified on the rating and serial number plate located on
the inside of the appliance door. DO NOT ATTACH THIS APPLIANCE TO A GAS SUPPLY FOR WHICH IT IS
NOT CONFIGURED!
DANGER
Before connecting new pipe to this appliance, the pipe must be blown out thoroughly to remove all foreign
material. Foreign material in the burner and gas valve will cause improper and potentially dangerous
operation.
DANGER
All connections must be sealed with a joint compound suitable for the gas being used and all connections
must be tested for leaks using a solution of soapy water before lighting any pilots. Never use matches,
candles, or any other ignition source to check for leaks. If gas odors are detected, shut off the gas supply
to the appliance at the main shut-off valve and immediately contact the local gas company or an authorized
service agency for service.
Adequate means must be provided to limit the movement of fryers without depending upon the gas line connections. If a
flexible gas hose is used, a restraining cable must be connected at all times when the fryer is in use.
NOTE:
The
installation must be inspected after it is complete to ensure it meets the intent of these instructions. The on-site
supervisor and/or operator(s) should be informed that the appliance is installed with restraints. If restraints are
removed to move fryer (cleaning beneath and behind, relocation, etc.), ensure that they are re-installed when
fryer is returned to its permanently installed position.
Propane Applications;
Proper Regulator Must Be Installed