background image

 

NOTICE

 

This appliance is intended for professional use only and is to be operated by qualified personnel only.  A 
Frymaster Factory Authorized Servicer (FAS) or other qualified professional should perform installation, 
maintenance, and repairs.  Installation, maintenance, or repairs by unqualified personnel may void the 
manufacturer’s warranty.   

 

NOTICE 

This equipment must be installed in accordance with the appropriate national and local codes of the 
country and/or region in which the appliance is installed.  

 

NOTICE TO U.S. CUSTOMERS 

This equipment is to be installed in compliance with the basic plumbing code of the Building Officials and 
Code Administrators International, Inc. (BOCA) and the Food Service Sanitation Manual of the U.S. Food 
and Drug Administration. 

 

 DANGER 

Improper installation, adjustment, maintenance or service, and unauthorized alterations or modifications 
can cause property damage, injury, or death.  Read the installation, operating, and service instructions 
thoroughly before installing or servicing this equipment.  Only qualified service personnel may convert 
this appliance to use a gas other than that for which it was originally configured.  

 

 DANGER 

Adequate means must be provided to limit the movement of this appliance without depending upon the 
gas line connection.  Single fryers equipped with legs must be stabilized by installing anchor straps.  If a 
flexible gas line is used, an additional restraining cable must be connected at all times when the fryer is 
in use.

 

 

 DANGER 

The front ledge of the fryer is not a step!   Do not stand on the fryer.  Serious injury can result from slips 
or contact with the hot oil. 

 

 DANGER 

Do not store or use gasoline or other flammable liquids or vapors in the vicinity of this or any other 
appliance. 

 

 DANGER 

Instructions to be followed in the event the operator smells gas or otherwise detects a gas leak must be 
posted in a prominent location.  This information can be obtained from the local gas company or gas 
supplier. 

 

NOTICE 

IF, DURING THE WARRANTY PERIOD, THE CUSTOMER USES A PART FOR THIS MANITOWOC FOOD 
SERVICE EQUIPMENT OTHER THAN AN UNMODIFIED NEW OR RECYCLED PART PURCHASED 
DIRECTLY FROM FRYMASTER, OR ANY OF ITS AUTHORIZED SERVICERS, AND/OR THE PART BEING 
USED IS MODIFIED FROM ITS ORIGINAL CONFIGURATION, THIS WARRANTY WILL BE VOID.  FURTHER, 
FRYMASTER AND ITS AFFILIATES WILL NOT BE LIABLE FOR ANY CLAIMS, DAMAGES OR EXPENSES 
INCURRED BY THE CUSTOMER WHICH ARISE DIRECTLY OR INDIRECTLY, IN WHOLE OR IN PART, DUE 
TO THE INSTALLATION OF ANY MODIFIED PART AND/OR PART RECEIVED FROM AN UNAUTHORIZED 
SERVICER. 

 

NOTICE 

The Commonwealth of Massachusetts requires any and all gas products to be installed by a 

licensed plumber or pipe fitter. 

Содержание ESG35T

Страница 1: ...PRINTED IN THE UNITED STATES For Service Call 318 865 1711 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 Price 6 00 8197049 OCTOBER 2013 ESG35T Installation Operation Manual...

Страница 2: ...t depending upon the gas line connection Single fryers equipped with legs must be stabilized by installing anchor straps If a flexible gas line is used an additional restraining cable must be connecte...

Страница 3: ...ay become unstable tip over and cause injury The appliance area must be free and clear of combustible material at all times NOTICE This appliance is only for professional use and shall be used by qual...

Страница 4: ...d be held firmly to keep the leg from bending or rotating while turning the foot to the required height For units equipped with casters Roll the unit into its final position and lock the front casters...

Страница 5: ...this appliance the pipe must be blown out thoroughly to remove all foreign material Foreign material in the burner and gas valve will cause improper and potentially dangerous operation DANGER All conn...

Страница 6: ...performing the following conversions When converting from natural gas to propane or vice versa the following procedures apply Burner orifices and pilot orifice MUST be replaced see page 1 5 for kit pa...

Страница 7: ...r Gas Manifold Burner Orifice Location Detail A Orifice 1 30 inch 33 mm 1 63 inch 41 mm 1 6 Gas Conversion Components Use the following components to convert from natural gas to propane and vice versa...

Страница 8: ...at the base of the frypot Use a long match to light the pilot Perform the following steps in sequence before lighting the pilot 1 Turn off the manual shut off valve on the incoming gas supply line 2 T...

Страница 9: ...g thermostat to the OFF position turn the gas valve knob to the OFF position and cover the frypot 2 3 Daily Operation 1 Do not allow grease to accumulate or harden on the frame body or flue of the fry...

Страница 10: ...N 2 3 2 5 Wiring Diagram 30 0 N O COM N C 200 2 5 0 OFF 1C 4C 3C HONEYWELL 1 2 P S I ON HONEYWELL PILOT 1 2 P S I PILOT ADJ 3 5 0 4 0 0 2C C HONEYWELL 1 2 P S I HIGH LIMIT OPERATING THERMOSTAT PILOT G...

Страница 11: ......

Страница 12: ...Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES Price 10 00 819 7049 OCTOBER 2013...

Отзывы: