Frymaster ESG35T Скачать руководство пользователя страница 3

ESG35T 

CHAPTER 1:  INSTALLATION INSTRUCTIONS

 

 

 

1-1

 

1.1 Safety 

Information 

 

Before attempting to operate your unit, read the instructions in this manual thoroughly.  Throughout this manual you will 
find notations enclosed in double-bordered boxes with the symbol 

.   The information contained in the box concerns 

actions or conditions that may cause or result in injury to personnel or damage to your system, and/or cause your system 
to malfunction. 

 

1.2 

General Installation Instructions 

 

 DANGER

 

Building codes prohibit a fryer with its open frypot of hot oil being installed beside an open flame of any 

type, including those of broilers and ranges. 

 

 DANGER

 

This appliance must be installed with sufficient ventilation to prevent the occurrence of unacceptable 

concentrations of substances harmful to the health of personnel in the room where it is installed. 

 

 DANGER

 

No structural material on the fryer should be altered or removed to accommodate placement of the fryer 

under a hood. 

 

 DANGER

 

Single fryers must be restrained to prevent tipping when installed in order to avoid the splashing of hot 

liquid.  The means of restraint may be the manner of installation, such as connection to battery of 

appliances or installing the fryer in an alcove, or by separate means, such as straps or chains. 

 

 DANGER

 

Do not attach an apron drainboard to a single unit.  The appliance may become unstable, tip over, and 

cause injury.  The appliance area must be free and clear of combustible material at all times.

 

 

NOTICE 

This appliance is only for professional use and shall be used by qualified personnel only.

 

 
CLEARANCE AND VENTILATION   

 

This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to 
combustible construction.  No clearance is required when installed adjacent to

 

non-combustible construction.  A 

minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer. 

 

The fryer flue opening must not be placed close to the intake of an exhaust fan, and the fryer must never have its flue 
extended in a "chimney" fashion.  An extended flue will change the combustion characteristics of the fryer.  To provide 
the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear 
must be kept clear and unobstructed. 

 

The fryer must be installed in an area with an adequate air supply and adequate ventilation.  Adequate distances must be 
maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank.  Filters should be installed at 
an angle of 45°.  Place a drip tray beneath the lowest edge of the filter.  For U.S. installation, NFPA standard No. 96 
states, "A minimum distance of 18-inches (450-mm) should be maintained between the flue outlet and the lower edge of 
the grease filter".  

Frymaster recommends that the minimum distance be 24-inches (600-mm) from the flue outlet to the 

bottom edge of the filter. 

 

 
 
 
 
 
 
 

Содержание ESG35T

Страница 1: ...PRINTED IN THE UNITED STATES For Service Call 318 865 1711 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 Price 6 00 8197049 OCTOBER 2013 ESG35T Installation Operation Manual...

Страница 2: ...t depending upon the gas line connection Single fryers equipped with legs must be stabilized by installing anchor straps If a flexible gas line is used an additional restraining cable must be connecte...

Страница 3: ...ay become unstable tip over and cause injury The appliance area must be free and clear of combustible material at all times NOTICE This appliance is only for professional use and shall be used by qual...

Страница 4: ...d be held firmly to keep the leg from bending or rotating while turning the foot to the required height For units equipped with casters Roll the unit into its final position and lock the front casters...

Страница 5: ...this appliance the pipe must be blown out thoroughly to remove all foreign material Foreign material in the burner and gas valve will cause improper and potentially dangerous operation DANGER All conn...

Страница 6: ...performing the following conversions When converting from natural gas to propane or vice versa the following procedures apply Burner orifices and pilot orifice MUST be replaced see page 1 5 for kit pa...

Страница 7: ...r Gas Manifold Burner Orifice Location Detail A Orifice 1 30 inch 33 mm 1 63 inch 41 mm 1 6 Gas Conversion Components Use the following components to convert from natural gas to propane and vice versa...

Страница 8: ...at the base of the frypot Use a long match to light the pilot Perform the following steps in sequence before lighting the pilot 1 Turn off the manual shut off valve on the incoming gas supply line 2 T...

Страница 9: ...g thermostat to the OFF position turn the gas valve knob to the OFF position and cover the frypot 2 3 Daily Operation 1 Do not allow grease to accumulate or harden on the frame body or flue of the fry...

Страница 10: ...N 2 3 2 5 Wiring Diagram 30 0 N O COM N C 200 2 5 0 OFF 1C 4C 3C HONEYWELL 1 2 P S I ON HONEYWELL PILOT 1 2 P S I PILOT ADJ 3 5 0 4 0 0 2C C HONEYWELL 1 2 P S I HIGH LIMIT OPERATING THERMOSTAT PILOT G...

Страница 11: ......

Страница 12: ...Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 TEL 1 318 865 1711 FAX Parts 1 318 219 7140 FAX Tech Support 1 318 219 7135 PRINTED IN THE UNITED STATES Price 10 00 819 7049 OCTOBER 2013...

Отзывы: