X20/X20S and Ethos v1.2.10 User Manual
Configure the Consumption sensor to use 'mAh' units, and set the range to suit your Lipo.
Select the source as 'Current2.4g'.
Add a new Logical Switch using the Delta (d>X) function to monitor the Consumption
sensor, and become True/Active every time the consumption reaches say 200mAh, or a
convenient fraction of the battery capacity.
Please note that for the consumption calculation you want the function to keep measuring
until your threshold is reached, so the Check Interval must be set to Infinite (i.e. ‘---‘).
Also the Min Duration can be set to greater than 0 so you can see it triggering while
debugging. At 0.0 it happens too fast to see it.
Add a Special Function to speak the total value of 'Consumption', i.e. the total mAh
consumed, every time 200mAh has been consumed.