background image

INSTALLATION AND MAINTENANCE MANUAL 

 

TRANSLATION OF THE  
ORIGINAL DOCUMENT 

For additional copies visit: 

www.frost‐trol.com

 

ALBORAN BM 

SOLID LINES 

Versión: -1 

-15- 

 

 

 
 

 
REMEMBER

The control components may only be operated by the technician responsible for the 
installation. The functions available to users are shutdown, start-up of the unit 
from  the  circuit      board    and    the    start-up    of    the    lighting    from    its  

corresponding  switches. 
 

 

3.3.

 

HOT SURFACES 

 
Some parts of the counter can reach high temperatures during operation. Before 
handeling them, make sure that they aren’t hot anymore or take the precautions 
necessary. These surfaces are marked by the symbol IEC 60417-5041 (202-10). 
 

 

Symbol IEC 60417-5041 (202-10) 

 
 

3.4.

 

PRODUCT LOADING 

 

Always check the working temperature before loading products inside. 
 

 

During cabinet operation, some parts of the cabinet may can reach high 

temperatures. Please, before its handling, make sure these surfaces are 
already cooled or take precautions. 

 

Please note the following points when loading the cabinet: 
 

 

To ensure the temperature maintenance, rotate food from front to 
back of the glass ceramic hob. 

 

Never lay out product directly onto the glass ceramic hob. Always 
use thermally stable containers. 

 

If exposed food is prepackaged, make sure that product package 
supports temperature. 

Содержание ALBORAN BM

Страница 1: ...ON OF THE ORIGINAL DOCUMENT For additional copies visit www frost trol com D004007 Versi n 1 WARNING Read the instructions before using the appliance INSTALLATION AND MAINTENANCE MANUAL ALBORAN BM SOL...

Страница 2: ...1 CABINET LOCATION 11 2 2 UPACKING 11 2 3 LEVELLING 11 2 4 ELECTRICAL CONNECTION 12 2 5 EQUIPOTENTIAL BONDING 12 2 6 CONNECTION TO THE WATER SUPPLY NETWORK 13 2 7 HANDELING HALOGEN LAMPS 13 2 8 CLEANI...

Страница 3: ......

Страница 4: ...less they are being supervised or had had instructions on how to use the appliance given by a person responsible for their safety Children must be supervised for preventing them from playing with the...

Страница 5: ...ails on the rating plate of the cabinet The cabinet must be properly connected to the earthing system Interior cleaning and disinfection could never be done in presence of food Looking at the lamp dur...

Страница 6: ...ductivity from these units and also so that the Marketing Director is able to gain the maximum commercial return possible Read this manual carefully and store it with the unit Pay particular attention...

Страница 7: ...keries butcher shops but not for mass food production Different versions depending on the type of glass complete the Alboran series curved TR or straight CU The cabinet has a wide range of optional ac...

Страница 8: ...1198 47 1 8 1777 70 3 3 2 1 3 1 8 HVTR129125BM0017 MODUL 1250 614 24 1 8 H 140 H 140 1780 70 1181 46 1 2 1 6 5 350 13 3 4 1 6 5 645 25 3 8 300 11 3 4 300 11 7 8 350 13 3 4 81 3 1 4 754 29 3 4 345 13 5...

Страница 9: ...DE AGUA 1 2 WATER INLET 1 2 PRISE D EAU 1 2 WASSEREINGANG 1 2 INFERIOR ON BOTTOM INF RIEUR UNTEN DESAG E DRAIN ECOULEMENT ABFLUSSANSCHLUSS 40mm CONEXI N EL CTRICA ELECTRICAL CONEXI N ACCORDEMENT L CTR...

Страница 10: ...representative for your country within 48 hours of receipt of the cabinet 1 5 DAMAGE SUSTAINED IN TRANSIT If the cabinet has sustained any damage in transit then you must make a claim with the Shippi...

Страница 11: ...ction Manager or the person responsible for the supermarket accordingly so that they can either specify another location or make the necessary modifications that would make the original location suita...

Страница 12: ...ety regulations in full Before plugging into the mains check that the supply voltage is the same as the voltage indicated on the nameplate The electricity supply should be adequate for maximum consump...

Страница 13: ...cessing it it is necessary to diassemble the rear plinth covers Once the pipe is connected to the water supply network make sure to open the valve in order to let the cabinet fill up automatically 2 7...

Страница 14: ...operating temperature Regulate the operating temperature by the thermostat situated in the control board of the cabinet Switch on or off the radiant heating depending on the type of foodstuffs expose...

Страница 15: ...hey aren t hot anymore or take the precautions necessary These surfaces are marked by the symbol IEC 60417 5041 202 10 Symbol IEC 60417 5041 202 10 3 4 PRODUCT LOADING Always check the working tempera...

Страница 16: ...IGINAL DOCUMENT For additional copies visit www frost trol com ALBORAN BM SOLID LINES Versi n 1 16 Rear doors only must be opened when necessary The cabinet doors should be closed as long as possible...

Страница 17: ...nly be handled and or repaired by authorised personnel 4 1 CLEANING ROUTINE Establish a routine cleaning schedule to ensure an adequate level of hygiene of your cabinet In this way you will ensure an...

Страница 18: ...e the cabinet products and put i tonto an adequate cold storage Apply a defrost Wait until the inner cabinet parts reach ambient temperature and no frost rests remain Don t use metallic or cutting obj...

Страница 19: ...exceed permissible pinch temperature as indicated in technical notice Respect burning position of the lamp as indicated in the technical documentation Avoid over voltage as this can adversely affect l...

Страница 20: ...e the following information Model Cabinet series number Manufacture year Part number according to spare parts cross section Length of the part if applicable Colour of the part if painted Left of right...

Страница 21: ...anufacture date Supply voltage Other details or photos would help to find a solution 6 2 FINAL SHUTDOWN We Frost trol SA declare this product is covered by Directive 2002 96 CE Waste Electrical and El...

Страница 22: ...member country with its own legislation binding equally on all those subject to its laws 6 3 DISMANTLING THE CABINET In accordance with the waste disposal regulations in each country and in respect o...

Страница 23: ...Frost trol S A Technical Department Avda del Castell Vell 176 12004 Castell n Spain Phone 0034 964 34 27 40 Fax 0034 964 21 51 48 e mail frost trol frost trol com www frost trol com...

Отзывы: