![FrontRow Pro Digital Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/frontrow/pro-digital/pro-digital_installers-manual_2339867015.webp)
12
Position ceiling sensor on the ceiling, centered
in the half of the room opposite the receiver
Receiver
Ceiling sensor placement
1. Positioning a ceiling sensor
A ceiling sensor is designed to ‘see’ the entire room at once, and so can often fill in any gaps in reception
by the main receiver. Use the following guidelines when installing a ceiling sensor:
Mentally divide the room in half, with the main receiver contained within one half.
Use a piece of tape to mark a spot on the ceiling that is centered within the other half of the room --
This is where you will install the ceiling sensor.
Assessing the individual characteristics of the environment is critical to achieving the best performance.
Poor coverage planning can dramatically reduce the performance of the system.
a.
DO NOT
mount the ceiling sensor or wall sensors in direct sunlight as it will greatly reduce performance.
b. The ceiling sensor must have a clear view of the coverage area and must be mounted parallel to the
floor to function optimally (figure 1). If drop lights are used in the room, wall sensors may be a better
option. Or, a drop mount* may be used to lower the ceiling sensor.
Light
Fixture
Ceiling Sensor
Orientation and coverage
optimized
*
*
not supplied by FrontRow
Classroom
Ceiling
Sensor
X
Sensor performance reduced: Not parallel
to floor AND blocked by light fixtures.
Figure 1: Ceiling Sensor Installation
Sensor cable
Receiver
Amplifier