FrontLine FTS4USB Скачать руководство пользователя страница 12

 

 

P a g e

 | 

10

 

CAPTURING DATA 

FTS4USB can capture data to a single file or series of files. Data capture can be initiated from the Control 
window, the Event Display or the Frame Display. You do not need any window other than the Control 
window open to capture data.   

 

To capture to a file, click the 

Start Capture 

 icon 

 . 

 

To stop capture to a file, click the 

Stop Capture

 icon 

.    Stopping capture means no new 

data will be added to the capture file until capture is resumed by clicking the Start Capture icon.  
The previously captured data remains in the file. 

 

To clear capture, click the 

Clear 

 icon 

.   

If you select Clear after selecting Stop, a dialog appears asking whether you want to save 
the data.   

 

You can click 

Save File

  and enter a file name when prompted .   

 

If you choose 

Do Not Save

, all data will be cleared. 

 

If you choose Cancel, the dialog closes with no changes. 

If you select the Clear icon 

while a capture is occurring

 

The capture stops. 

 

A dialog appears asking if you want to save the capture 

 

You can select Yes and save the capture or select No and close the dialog.  In 

either case, the existing capture file is cleared and a new capture file is started. 

 

 

If you choose Cancel, the dialog closes with no changes. 

If the file becomes full, data capture will begin to wrap, which means the oldest data will be overwritten 
by new data. You can tell how full the file is by checking the bar graphic next to Capture Status on the 
status bar of the Control window. If you do not want the file to wrap, choose 

System Settings

 from the 

Options

 menu on the Control window and uncheck the 

Wrap File

 box. If you have 

Wrap File

 unchecked, 

then capturing will stop when the file becomes full. 
Go to th

Analyzing Data

 section next in this guide to learn how to use Frontline analysis tools. 

 

 

 

 

 

 

 

Содержание FTS4USB

Страница 1: ...or written authorization of Frontline Test Equipment Inc FTS Frontline Frontline Test System and ComProbe are registered trademarks of Frontline Test Equipment Inc FTS4BT is a trademark of Frontline T...

Страница 2: ...5 Connecting only one Device Under Test 5 Connecting more than one Device Under Test 6 Connection tips 7 Opening Selecting Data Capture Method 8 Capturing data 10 Analyzing Data 11 Control Window 11 F...

Страница 3: ...S PC with Windows XP 32 bit Service Pack 2 or higher Windows 7 32 and 64 bit Pentium 2 GHz processor RAM Requirements 2 GB minimum 50 MB free Hard Disk Space capture file size is limited only by disk...

Страница 4: ...ComProbe I USB Captures and decodes USB bus activities and transactions USB ComProbe II Bluetooth HCI Captures and decodes Bluetooth data USB and USB Setup data will be filtered out USB ComProbe II US...

Страница 5: ...onnection The front of the analyzer has three USB connections one for the device being tested one for the PC the device is normally connected to and one digital I O port Figure 1a Figure 1a Front Pane...

Страница 6: ...side also includes a mini DIN 9 connector which serves as a connection to the digital inputs and outputs Figure 1d Its pin outs and the cable coloring for the included cable are described in Figure 3d...

Страница 7: ...analyzer please ensure it is connected on a high speed USB 2 0 enabled host controller before contacting our technical support Connecting only one Device Under Test The most straightforward configurat...

Страница 8: ...evices this analysis must necessarily involve a USB hub In this way you can ensure that all the devices to be analyzed are in fact below the analyzer You should be aware that the analyzer will record...

Страница 9: ...ceed the recommended maximum lengths the cable connected to the analysis computer should not exceed 15 feet and the total length of the cables connected to the test computer and the device under test...

Страница 10: ...Start menu or from the Desktop folder 2 Select Frontline FTS4USB The Select Data Capture Method dialog appears Figure 3a Figure 3a Data Capture Methods Notice that the four sniffing methods that we i...

Страница 11: ...P a g e 9 3 Select one of the options 4 Select Run FTS4USB will open with the Control Window Figure 3b visible Figure 3b Control WIndow Now you are ready to begin capturing and analyzing data...

Страница 12: ...ill be cleared If you choose Cancel the dialog closes with no changes If you select the Clear icon while a capture is occurring The capture stops A dialog appears asking if you want to save the captur...

Страница 13: ...FTS4USB is organized around this window The Control window allows you to control data capture and access the other windows used to view data While there are a number of dialogs you can use to analyze...

Страница 14: ...gure 4c stretches across the top of the display Each line in the Summary Pane represents one frame except when running in one of the USB HCI Sniffing modes where each line represents one transaction F...

Страница 15: ...Frame Errors Frame numbers in red indicate an error in the frame Select the frame and look at the top of the Decode pane to determine the type of error Scrolling versus Static View Click the Lock Resu...

Страница 16: ...re updated with information such as the time the event occurred for data bytes the time the byte was captured the value of the byte in Hex Decimal Octal and Binary any errors associated with the byte...

Страница 17: ...start of an interaction in one Frame Display and the end of that same interaction in the other and compare the two Bookmarks Bookmarks let you mark frames of interest so they can be easily found later...

Страница 18: ...n common problems as well as software upgrades and utilities to use with our products Web http www fte com click Support Email tech_support fte com If you need to talk to a technical support represent...

Отзывы: