72
CAUTION!
Risk of injury due to an electric shock
Although Fronius devices comply with all relevant standards, the high frequency ignition
can transmit a harmless but noticeable electric shock under certain circumstances.
► Use prescribed protective clothing, especially gloves!
► Only use suitable, completely intact and undamaged TIG hosepacks!
► Do not work in damp or wet environments!
► Take special care when working on scaffolds, work platforms, in forced positions, in
tight, difficult to access or exposed places!
Pulse TAC display
off / on
Factory setting: on
This menu item can be used to hide the pulsing and tacking parameters on the control pan
-
el in the welding parameter overview.
Ignition time out
Period of time until the safety cut-out following failed ignition
0.1 - 9.9 s
Factory setting: 5 s
Arc break monitoring
Period of time until the safety cut-out following an arc break
0.1 - 9.9 s
Factory setting: 1.0 s
IMPORTANT!
Arc break monitoring is a safety function and cannot be deactivated.
A description of the arc break monitoring function can be found in the "TIG Welding" sec
-
tion on page
TIG Comfort Stop sensibility - comfort stop sensitivity
The parameter is only available if the "Trigger" parameter is set to "off".
oFF / 0.6 - 3.5 V
Factory setting: 1.5 V
At the end of the welding process, an automatic shutdown of the welding current follows a
significant increase of the arc length. This prevents the arc from having to be unnecessarily
lengthened when lifting the TIG welding torch.
Содержание TransTig 170
Страница 2: ...2...
Страница 6: ...6...
Страница 18: ...18...
Страница 19: ...General Information...
Страница 20: ......
Страница 24: ...24...
Страница 25: ...Operating controls and connections...
Страница 26: ......
Страница 33: ...Installation and Startup...
Страница 34: ......
Страница 41: ...Welding Mode...
Страница 42: ......
Страница 62: ...62...
Страница 63: ...Setup Settings...
Страница 64: ......
Страница 79: ...Troubleshooting and Maintenance...
Страница 80: ......
Страница 87: ...87 EN US Disposal Materials should be disposed of according to valid local and national regulations...
Страница 88: ...88...
Страница 89: ...Appendix...
Страница 90: ......
Страница 92: ...92 Safety symbol S Max shielding gas pressure 5 bar 73 psi Noise emissions LWA 68 0 dB A...
Страница 98: ......
Страница 99: ......