45
EN
Connecting the
interconnecting
hosepack
IMPORTANT!
Gas-cooled systems are not fitted with a cooling device.
The water connections therefore do not need to be connected for gas-cooled systems.
1
2
Connecting the
gas cylinder
WARNING!
If gas cylinders topple over, there is a risk of very serious injury and damage.
When using gas cylinders
► Place them on a solid, level surface in such a way that they remain stable
► Secure the gas cylinders to prevent them from falling over
► Fit the VR holder option
Follow the gas cylinder manufacturer's safety rules.
1
-
Briefly open the gas cylinder valve to
blow off any dust or dirt
-
Check the seal on the pressure regula
-
tor
NOTE!
US devices are supplied with an adapter for the gas hose:
► Seal male thread spacers on the gas solenoid valve using suitable means before
screwing on the adapter.
► Test the adapter to ensure that it is gas-tight.
1
1
2
7
4
5
6
3
2
1