19
EN
Nothing happens
on control panel
(TPS 2700)
(continued)
5V, +15V, -
15V on UST?
Check/change control
panel/ribbon cable
Yes
Unplug X4 from UST
No
A
5V, +15V, -
15V on UST?
Change VAC shunt
Yes
Unplug X2 from UST
No
5V, +15V, -
15V on UST?
Check/change control
panel/ribbon cable
Yes
Unplug X6 from UST
No
5V, +15V, -
15V on UST?
Change BPS
Yes
Change UST
No
End