18
Start
Voltage OK on prima-
ry rectifier V1=320V/
560V DC?
Check mains cable,
mains switch, line
filter, rectifier and
supply voltage
No
Voltage on intermedi-
ate circuits 1 and 2 >
250V DC?
Change BPS
Are LEDs +5V, +12V
flashing on the ASU 27,
as well as LED for mains
400V at 400V Unom,
and LED for mains 230V
at 230V Unom?
Change ASU 27
On MV power sources
Change BPS
+24V int/ext LEDs
flashing on UST?
Switch power source
off, unplug plug X3
from UST, switch
power source on
Change NT 24
Yes
Yes
24V int/ext
LEDs on NT 24?
Switch power source
off, plug X3 plug into
UST and unplug X7,
switch power source
on
No
No
Check cooling unit
24V int/ext
LEDs on UST?
Yes
No
Yes
No
Change BPS
No
Yes
Yes
A
Nothing happens
on control panel
(TPS 2700)