16
Poor ignition and
welding proper-
ties with „TIG
welding“
End
Correct shielding gas connected,
and l/min set correctly?
Start
Gas-test button: Shielding gas
flowing out?
Welding torch and grounding
(earthing) cable OK?
Parameters set correctly?
Check shielding gas solenoid
valve, including control
Check welding torch and groun-
ding (earthing) cable
-
Check settings on control panel
-
Check set-up parameters
-
Possibly reset to factory set-
tings (FAC) (see operating instruc-
tions)
Check whether power source OK,
and check application
Connect correct shielding gas and
check l/min
Yes
No
No
No
Yes
Yes
Yes
No