Care, maintenance and disposal
General
Under normal operating conditions, the power source requires only a minimum of care
and maintenance. However, some important points must be noted to ensure that the
welding system remains in a usable condition for many years.
WARNING!
An electric shock can be fatal.
Before opening the device
▶
Move the mains switch to the "O" position
▶
Unplug the device from the mains
▶
Put up an easy-to-understand warning sign to stop anybody inadvertently reconnect-
ing it
▶
Using a suitable measuring instrument, check to make sure that electrically charged
components (e.g. capacitors) have been discharged
At every start-up
-
Check mains plug, mains cable, welding torch, interconnecting hosepack and
grounding (earthing) connection for damage
-
Check that the device has an all-round clearance of 0.5 m (1ft. 8in.) to ensure that
cooling air can flow and escape unhindered
NOTE!
Air inlets and outlets must never be covered, not even partially.
Every 2 months
-
clean air filter
Every 6 months
-
Dismantle device side panels and clean inside of device with dry reduced com-
pressed air
NOTE!
Risk of damage to electronic components.
Do not bring the air nozzle too close to electronic components.
-
If a lot of dust has accumulated, clean the cooling-air ducts
Disposal
Dispose of in accordance with the applicable national and local regulations.
38