97
g
tu2 | xxx
Remark: xxx stands for a temperature value
Cause:
Undertemperature in the power source secondary circuit
Remedy:
Place power source in a heated room and allow to warm up
tu3 | xxx
Remark: xxx stands for a temperature value
Cause:
Undertemperature in the wire-feed unit motor
Remedy:
Place wire-feed unit in a heated room and allow to warm up
tu4 | xxx
Remark: xxx stands for a temperature value
Cause:
Undertemperature in the welding torch
Remedy:
Place welding torch in a heated room and allow to warm up
tu5 | xxx
Remark: xxx stands for a temperature value
Cause:
Undertemperature in the cooling unit
Remedy:
Place cooling unit in a heated room and allow to warm up
tu6 | xxx
Note: xxx stands for a temperature value
Cause:
Undertemperature on the output choke of the power source
Remedy:
Place power source in a heated room and allow it to warm up
tu7 | xxx
Note: xxx stands for a temperature value
Cause:
Undertemperature in the power source
Remedy:
Place power source in a heated room and allow it to warm up
no | H2O
Cause:
Coolant flow rate too low
Remedy:
Check coolant flow rate and cooling unit, including cooling circuit (for mini-
mum coolant flow, see "Technical Data" section in the device operating in-
structions)
hot | H2O
Cause:
The coolant temperature is too high
Remedy:
Allow cooling unit and cooling circuit to cool down, until "hot | H2O" is no long-
er displayed. Open the cooling unit and clean the cooler, check fan is working
properly. Robot interface or field bus coupler: before resuming welding, set
the "Source error reset" signal.
no | Prg
Cause:
No preconfigured program has been selected
Remedy:
Select a configured program
Содержание TRANS STEEL 3500 C0MPACT
Страница 1: ...T YDELLIST HITSAUSTA TRANS STEEL 3500 C0MPACT Operating Instructions Spare Parts List v 01 2012 ENG...
Страница 2: ...0...
Страница 4: ...2...
Страница 8: ...6...
Страница 22: ...20...
Страница 23: ...General information...
Страница 24: ......
Страница 28: ...26...
Страница 29: ...Control elements and connections...
Страница 30: ......
Страница 38: ...36...
Страница 39: ...Installation and commissioning...
Страница 40: ......
Страница 46: ...44 3 IMPORTANT Tie the phase conductors near the luster terminal using cable ties...
Страница 55: ...53 g Contact pressure standard values U grooved rollers Steel 4 5 CrNi 4 5 Tubular cored electrodes 2 3...
Страница 59: ...Welding...
Страница 60: ......
Страница 64: ...62 GPr GPo I I S SL SL I E t I...
Страница 75: ...73 g Number 4 Number 5...
Страница 76: ...74...
Страница 77: ...Setup settings...
Страница 78: ......
Страница 90: ...88...
Страница 91: ...Troubleshooting and maintenance...
Страница 92: ......
Страница 106: ...104...
Страница 107: ...Annex...
Страница 108: ...106 Spare parts list TransSteel 3500c...
Страница 110: ...108...
Страница 112: ...Maahantuonti ja myynti Pronius Oy Keisarinviitta 20 B 33960 Pirkkala 358 0 44 200 9060 info pronius fi www pronius fi...