76
Closing the
housing
Fitting the
varistor
Note!
Before any work involving the soldering iron, always clean the tip of the
soldering iron.
- Use the soldering iron to heat up the soldering points (76), and remove the liquid
soldering tin as completely as possible with the aid of a suction pump or solder
absorption strand.
Note!
There is no need to ensure any particular polarity when mounting the
varistor.
If the soldering points (76) are burned-out,
it is also possible to insert the varistor into
the repair soldering points (77).
- Carefully insert the varistor into the
soldering points (76), and hold it in
place
Note!
Only use special
electronics soldering tin for
soldering on the varistor
(76)
(77)
- Solder the varistor to the soldering points (76) or (77)
Fig.6
(75)
(74)
- Plug the mains-cable earthing
conductor (74) back on
- Plug the heat-sink earthing conductor
(75) back on
Fig.7
- Plug the “housing earth conductor”
(36) onto the housing box, in the
correct position
- Replace the housing box
- Screw the 5x25-TX20 screw (35) back
onto the rear of the housing
- Screw the 5x25-TX20 screw (34) back
onto the front of the housing
- Fit the carrying strap back on again
- Insert the board insulator (37)
- Insert the housing stiffening element
(21)
(34)
(36)
(35)
Fig.9
(21)
(37)
Fig.8