66
- Arrange the transformer leads (44) for
the LCA 15 board as shown in Fig.15,
and stow away the WAGO connectors
(45)
- Carefully place the LCA15 board (1),
underside first, onto the heat sink
(1)
- To position the LCA15 board (1), gently
screw the M4 screw (43) into the
M4x17 earthing stud (48) - see Fig.10 -
by hand.
(43)
(1)
Fitting the LCA15
board
(continued)
Fig.13
Fig.14
(45)
(45)
Fig.15b
Fig.15a
Fig.15c
(45)
(44)
(45)