![Fronius Symo 10.0-3-M Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/fronius/symo-10-0-3-m/symo-10-0-3-m_quick-start-manual_2339221024.webp)
+
Fronius Inverter
Installation
Serial No. on rating plate
DRM‘s for
Australia
I9
4/8
I7
2/6
I5 IO3
CL/0
IO1 GND GND D-
3/7
I8
1/5
I6 I4
RG/0
IO2
12V+
12V+
IO0
D+
?
Fronius Inverter
Operating
Instructions
* Serial Number Sticker for Customer Use, 57 x 20 mm
** DRMs for
Australia
for Customer Use, 67 x 20 mm
*
**
*
**
Application example
DRM‘s for
Australia
I9
4/8
I7
2/6
I5 IO3
CL/0
IO1 GND GND D-
3/7
I8
1/5
I6 I4
RG/0
IO2
12V+
12V+
IO0
D+
DRM‘s for
Australia
I9
4/8
I7
2/6
I5
IO3
CL/0
IO1
GN
DG
ND
D-
3/7
I8
1/5
I6
I4
RG/0
IO2
12
V+
12
V+
IO0
D+
2
only Australia
1
Conduit
Conduit
AC~
Condensation
Air circulation
Inside
Outside
DC=
Conduit
Conduit
AC~
Inside
Outside
DC=
4
3
2
Permanently elastic sealant
Seal all used conduits!
Seal every incoming and every outgoing conduit!
Seal both conduit ends!
1
Conduit
Inverter housing
Conduit fitting
Permanently elasti
c
sealant
1
1
rigid or flexible
59
58
Australia - Conduits
61
60
NOTE!
Condensation within the conduits
can damage the inverter or components of
the photovoltaic systems.
To avoid undesirable air circulation and
condensation in the conduits,
– seal all conduits being used with a per-
manently elastic sealant,
– seal every incoming and outgoing con-
duit,
– seal both conduit ends.
Serial Number Sticker for Customer Use
57