Technical data
Selectiva 16 kW
220 V
Mains voltage (-10%/+30%)
1)
Optional:
3~ NPE 220 V/50/60 Hz
3~ PE 220 V/50/60 Hz
Mains fuse protection
2)
32 A
Minimum mains lead cross section
Selectiva 4120
Selectiva 4140/4160
4 mm² (0.0062 in.²)
6 mm² (0.0093 in.²)
Duty cycle
100%
EMC device class
B
Standby usage
6.9 W
Protection class
I
Max. permitted mains impedance Z
max
on PCC
3)
According to the "Device-specific
data" table below
Degree of protection
4)
IP 20
Overvoltage category
III
Operating temperature
5)
-20°C to +40°C
(-4°F to 104°F)
Storage temperature
-25°C to +80°C
(-13°F to 176°F)
Relative humidity
max. 85%
Maximum altitude above sea level
3000 m (9842 ft)
Mark of conformity
according to rating plate
Product standard
EN 62477-1
Dimensions L x W x H
647 x 247 x 392 mm
(25.47 x 9.72 x 15.43 in.)
Weight (with standard mains and charging leads) 34.84 kg (76.81 lb)
Degree of contamination
3
1)
The device is approved for operation on neutral-earthed mains networks with a
maximum outer conductor nominal voltage of 220 V.
2)
Nothing other than a type B residual current circuit breaker should ever be used
for connecting the device to the mains. The earth leakage current is less than 3.5
mA.
3)
Interface to a 127/220 V and 50 Hz public grid.
4)
For indoor use only, do not expose to rain or snow.
5)
A high ambient temperature may result in power degradation (derating).
59