4
MAINS ON/OFF SWITCH
(see Fig.9)
DIGITAL-AMMETER
-
Indicator of the main current
Command value
ð
desired welding current
Actual value
ð
actual welding current
DIGITAL-VOLTMETER
-
Indicator of the welding voltage
FUNCTION BUTTON
a)
2-step operation
b)
4-step operation
c)
2-step operation
+
d)
4-step operation
+
-
Arc force control and hot-start devices are out of action
-
When the TR 50mc, TR 51mc and TR 52mc remote-control
units are used, the system switches over to the operating
mode in question automatically
-
LED indicators or resp. + or + lights up
e) MANUAL ELECTRODE WELDING
-
LED indicator lights up and the digital voltmeter indicates
the open-circuit voltage.
-
The welding characteristics are governed by the values for
ARC FORCE and HOT-START which are fixed in the machi-
ne itself.
-
It is possible to influence these parameters from outside via
the TPmc remote control unit and the inert menue at function
selector switch position
LED INDICATOR for manual electrode welding
-
Select via function button
-
LED indicator lights up
(for main current I
H
)
only at welding
-
Welding current is present in the current sockets ,
-
Welding current is either adjusted with the main current re-
gulator , or via the dial on the TPmc remote control unit
LED INDICATOR for contact ignition
-
Select via function button
-
Lights up together with either LED or LED
-
To ignite the arc, touch the workpiece with the tungsten
electrode after pressing the torch trigger.
-
The short-circuit current flowing when contact is made bet-
ween the electrode and the workpiece corresponds to the
minimum current.
Where to use contact ignition:
Whenever the HF used in
contact-free ignition would cause external interference.
LED INDICATOR FOR 4-STEP MODE
4-step mode
4-step mode
- without intermediate lowering
-
In the manual or automatic welding modes, for flawless
welding joints
-
Pre-settable parameters such as gas pre-flow, start arc,
upslope time, main current, downslope time, crater-fill cur-
rent and gas post-flow time
-
In the "PRESETTINGS LEVEL ---" program-level (see "Wor-
king with the program-levels"), parameter TIG, the setting
for SFS must be set to "OFF"
Functional sequence
(Fig.4):
1. Pull back and hold the torch trigger
-
Gas pre-flow time elapses
-
Arc ignites at the pre-set value for start-arc current I
S
(with
HF ignition: HF cuts out automatically after ignition)
-
LED indicator lights up
}
}
TIG-welding with
HF-ignition
TIG-welding with
contact ignition
2. Release trigger
-
Welding current rises via the pre-set upslope to the value set
on dial for the welding current I
H
-
LED lights up
3. Pull back and hold the torch trigger once again
-
Welding current drops during the pre-set time
(downslope,
dial )
until it reaches the value set for the crater-fill current
I
E
(dial , crater-filling)
-
LED lights up
4. Release the torch trigger
-
Arc goes out
-
The internally pre-set gas post-flow time elapses
4-step mode
- with intermediate lowering (Fig.4a)
-
Activated from TIG torch with double-pushbutton function
-
Intermediate lowering down to reduced current I
E
:
- Facility for lowering the welding current from the main
current to the reduced current I
E
and back, without
interrupting the welding sequence
-
In the "PRESETTINGS LEVEL ---" program-level (see "Wor-
king with the program-levels"), parameter TIG, the setting
for SFS must be set to "OFF"
Start
of
cycle
Gas
pre-flow
time
Current
rises
via
upslope
Current
drops
via
downslope
Gas
post-flow
time
End
of
welding
Crater-fill
current
Pull back and hold the torch trigger
Release the torch trigger
Release the torch trigger
Arc
ignites
with
start-arc
current
I
S
Welding
with
pre-set
main
current
I
H
Fig. 4
Functional sequence in 4-step mode - without intermediate lowering
Pull back and hold the torch trigger
I
S
I
H
I
E
I
t
Push forward and hold the torch trigger
Release the torch trigger
Release the torch trigger
Fig. 4a
Functional sequence in 4-step mode - Variant I - with intermediate
lowering
Pull back and hold the torch trigger once again
I
S
I
H
I
E
I
t
Pull back and hold the torch trigger
Release the torch trigger
I
E
I
H
Start
of
cycle
Gas
pre-flow
time
Current
rises
via
upslope
Current
drops
via
downslope
Gas
post-flow
time
End
of
welding
Crater-fill
current
Arc
ignites
with
start-arc
current
I
S
Welding
with
pre-set
main
current
I
H
Current
rises
via
upslope
Current
drops
via
downslope
Welding
with
pre-set
main
current
I
H
Crater-fill