Information on
leaks
The following information on leaks does not apply to the FK 4000 Rob.
The shaft sealing surfaces inside the coolant pump are lubricated by the coolant, mean-
ing that a certain leakage flow should always be expected. A low leakage flow is permit-
ted.
The coolant pump requires a certain warm-up time after being started for the first time or
upon restarting after a long period of downtime. An increased leakage flow can occur
during this warm-up phase. The leakage flow will normally sink back down to a low level
after the warm-up phase. If this is not the case then contact After-Sales Service.
Warning notices
on the device
The cooling unit is fitted with safety symbols and a rating plate. The rating plate and
safety symbols must not be removed or painted over. The symbols warn against operat-
ing the equipment incorrectly, as this may result in serious injury and damage.
4 bar (0.4 MPa)
2 kW
P
1l/min
1~
50-60 Hz
IEC 60 974-2/-10 Cl.A
IP 23
0.6 A
U
1
400 V
p
max
A-4600 Wels
www.fronius.com
Ser.No.:
Part No.:
Type:
p
max
I
max
Welding is dangerous. The following basic requirements must be met to
ensure the equipment is used properly:
-
Welders must be sufficiently qualified
-
Suitable protective equipment must be used
-
All persons not involved must be kept at a safe distance from the cool-
ing unit and the welding process
Do not use the functions described here until you have thoroughly read and
understood the following documents:
-
these operating instructions
-
all the operating instructions for the system components, especially
the safety rules
Do not dispose of used devices with domestic waste. Dispose of them
according to the safety rules.
17
EN
Содержание FK 4000
Страница 2: ......
Страница 40: ...40...
Страница 41: ...Troubleshooting 41...
Страница 42: ...42...
Страница 51: ...51 EN...