4
Fig. 4 Quick switch off plug (3-pole)
Connect the
interface with the
„Binder“ plug to
the robot control
Fig. 5 Control signals plug (5-pole)
The connection socket for quick switch off is designed as a 5-pole Binder circular con-
nector on the interface. The socket has 2 coded pins. A 3-pole Binder circular connector
must be connected.
Important!
The pin allocation corresponds to the 3-pole plug.
As long as Pin 1 is connected to Pin 2, no start signal is given to the power source.
The connection socket for the control signals is designed as a 5-pole Binder circular
connector on the interface. A 5-pole Binder circular connector must be connected.
I-Specified
Approval
I-ACTUAL
U-ACTUAL
GND
Switch off
GND
not used
Check control
level
The control level can be adjusted individually on the PLI10 board using a jumper.
Caution!
Incorrectly set control levels can lead to damage to the system.
Before initial operation of the power source the control levels set must be
checked and adjusted if necessary.