background image

Fronius prints on elemental chlorine free paper (ECF) sourced from certified sustainable forests (FSC).

/ Perfect Charging / Perfect Welding / Solar Energy

TransSynergic 4000/5000
TransPuls Synergic 2700
TransPuls Synergic
3200/4000/5000
TIME 5000 Digital
CMT 4000 Advanced

EN

Operating instructions

MIG/MAG power source

42,0426,0001,EN 023-17092020

Содержание CMT 4000 Advanced

Страница 1: ...ified sustainable forests FSC Perfect Charging Perfect Welding Solar Energy TransSynergic 4000 5000 TransPuls Synergic 2700 TransPuls Synergic 3200 4000 5000 TIME 5000 Digital CMT 4000 Advanced EN Ope...

Страница 2: ...Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 3: ...stallation location and during transport 17 Safety measures in normal operation 17 Commissioning maintenance and repair 18 Safety inspection 18 Disposal 19 Safety symbols 19 Data protection 19 Copyrig...

Страница 4: ...ombinations special functions 57 Displaying the feeder inching speed 57 Displaying the gas pre flow and gas post flow time 57 Displaying the software version 58 Yard control panel 59 Yard control pane...

Страница 5: ...0 Digital 89 General 89 Fitting the system components overview 89 Fixing the strain relief device in place 90 Connecting the interconnecting hosepack 90 Connecting the gas cylinder 91 Establishing a g...

Страница 6: ...rt Stop option 118 TIG welding with TIG Comfort Stop 119 MMA welding 121 Safety 121 Prerequisite 121 Preparation 121 Manual metal arc welding 122 Corrections during welding 122 Adjusting parameters fo...

Страница 7: ...CMT control panels 153 Parameters for MIG MAG welding in the Setup menu level 2 153 Parameters for operating power sources in parallel in the Setup menu level 2 156 Parameters for TimeTwin Digital in...

Страница 8: ...TIME 5000 Digital 200 CMT 4000 Advanced 201 CMT 4000 Advanced MV 202 Welding program databases 204 Explanation of symbols 204 Setting up a welding program database example 204 Terms and abbreviations...

Страница 9: ...commissioning operating maintaining and servicing the device must be suitably qualified have sufficient knowledge of welding and read and follow these operating instructions carefully The operating i...

Страница 10: ...31 F Relative humidity up to 50 at 40 C 104 F up to 90 at 20 C 68 F The surrounding air must be free from dust acids corrosive gases or substances etc Can be used at altitudes of up to 2000 m 6561 ft...

Страница 11: ...isor and regulation filter Wear regulation protective goggles with side protection behind the protective visor Wear stout footwear that provides insulation even in wet conditions Protect the hands wit...

Страница 12: ...d components should therefore be studied carefully Recommendations for trade fair scenarios risk management measures and for identify ing working conditions can be found on the European Welding Associ...

Страница 13: ...wer source is switched on Double the open circuit voltage of a power source can occur between the welding elec trodes of two power sources Touching the potentials of both electrodes at the same time m...

Страница 14: ...idential and industrial areas This is also true for residential areas in which the energy is supplied from the public low voltage mains EMC device classification as per the rating plate or technical d...

Страница 15: ...injury piercing of the hand injuries to the face and eyes etc Therefore always keep the welding torch away from the body devices with wire feed unit and wear suitable protective goggles Never touch th...

Страница 16: ...t and reduce welding quality Meet the following requirements regarding shielding gas quality Solid particle size 40 m Pressure condensation point 20 C Max oil content 25 mg m Use filters if necessary...

Страница 17: ...y set up and operate the device in accordance with the degree of protection shown on the rating plate When setting up the device ensure there is an all round clearance of 0 5 m 1 ft 7 69 in to ensure...

Страница 18: ...ebsite Check the coolant level before starting to weld while the system is still cool Commissioning maintenance and repair It is impossible to guarantee that bought in parts are designed and manufactu...

Страница 19: ...elevant product standards of the EN 60 974 series Fronius International GmbH hereby declares that the device is compliant with Directive 2014 53 EU The full text on the EU Declaration of Conformity ca...

Страница 20: ...20 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 21: ...General information 21 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 22: ...22 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 23: ...the power sources is coupled with a digital sig nal processor The central control and regulation unit and the signal processor control the entire welding process During the welding process the actual...

Страница 24: ...sources come with extra warning notices affixed to the unit The warning notices must NOT be removed or painted over Nur vorhanden bei Stromquelle TPS 2700 und auf Drahtvorsch ben 24 Toowoomba Welding...

Страница 25: ...l objects away 1 Electric shock can kill 1 1 Wear dry insulating gloves Do not touch electrode with bare hand Do not wear wet or damaged gloves 1 2 Protect yourself from electric shock by insulating y...

Страница 26: ...tainers 4 Arc rays can burn eyes and injure skin 4 1 Wear hat and safety glasses Use ear protection and button shirt collar Use welding helmet with correct shade of filter Wear complete body protectio...

Страница 27: ...se option CrNi edition The CrNi edition power sources were developed for perfect and careful processing of CrNi Special CrNi welding programs assist in the professional processing of high grade steels...

Страница 28: ...owing features bring about faster welding speeds with an increase in deposition rate of up to 30 Power module with high voltage reserves High performance welding programs Specially selected shielding...

Страница 29: ...in which the power source is to be used Overview 1 2 3 4 5 6 7 11 10 9 8 FR ON IU S Overview of system components Legend 1 Human hosepack boom 2 Remote controls 3 Welding torches 4 Wire feed units 5...

Страница 30: ...30 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 31: ...Control elements and connections 31 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 32: ...32 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 33: ...actual control elements on your device but these controls function in exactly the same way Safety WARNING Danger from incorrect operation Possible serious injury and damage to property Do not use the...

Страница 34: ...are not available and cannot be retrofitted MIG MAG pulse synergic welding Job mode TIG welding Manual metal arc welding Spot welding Any changes to the Welding current and Arc length correction para...

Страница 35: ...one parameter is selected then the synergic function means that all other parameters are automatically set as well 3 Left digital display 4 Sheet thickness LED lights up when the sheet thickness param...

Страница 36: ...d gas flow rate on the pressure regulator Gas will flow out for 30 s after pressing the gas test button Press the button again to stop the gas test flow before the end of this period Key combina tions...

Страница 37: ...ng database e g 0 029 M0029 Press the Material button 12 again to display the number of the wire feed unit A or B in the case of twin head mounts and the software version of the wire feed unit e g A 1...

Страница 38: ...pply equally to the CrNi and Steel control pan els Comfort control panel 14 4 1 28 26 25 5 18 15 12 11 10 3 6 9 7 16 8 27 24 23 22 13 2 19 17 20 21 No Function 1 Feeder inching button for feeding the...

Страница 39: ...F1 indicator indicates that the current input PushPull drive is switched on Wire feed rate drive current input indicator indicates that the wire feed rate drive current input is switched on If the in...

Страница 40: ...LED lights up when the arc length correction parameter is selected 14 Droplet detachment correction arc force dynamic correction arc force dynamic LED lights up when the droplet detachment correction...

Страница 41: ...ed under job numbers F3 indicator indicates the real energy inputs in KJ The real energy input must be activated in level 2 of the Setup menu parameter EnE If the indic ator is not activated the coola...

Страница 42: ...ights up 26 Intermediate arc indicator a spatter prone intermediate arc occurs between the short arc and the spray arc The intermediate arc indicator lights up to alert you to this critical area 27 St...

Страница 43: ...ftware ver sion of the wire feed unit and the arc burning time The software version is displayed Press the Material button 24 to display the version number of the welding database e g 0 029 M0029 Pres...

Страница 44: ...er in the Setup menu 2 Keylock switch optional When the key is in the horizontal position the following functions are dis abled Selecting the welding process using the Process button s 20 Selecting th...

Страница 45: ...1 indicator LED lights up when the F1 indicator parameter is selected 5 Wire feed unit drive current input indicator LED lights up when the wire feed unit drive current input indicator parameter is se...

Страница 46: ...isplayed Job No In the job mode process for retrieving parameter records stored under job numbers F3 indicator indicates the real energy inputs in KJ The real energy input must be activated in level 2...

Страница 47: ...ights up 24 Intermediate arc indicator a spatter prone intermediate arc occurs between the short arc and the spray arc The intermediate arc indicator lights up to alert you to this critical area 25 St...

Страница 48: ...software ver sion of the wire feed unit and the arc burning time The software version is displayed Press the Material button 22 to display the version number of the welding database e g 0 029 M0029 Pr...

Страница 49: ...the Fdi parameter in the Setup menu 2 Keylock switch optional When the key is in the horizontal position the following functions are dis abled Selecting the welding process using the Process button s...

Страница 50: ...other parameters including the welding voltage parameter are automatically set as well 4 F1 indicator LED lights up when the F1 indicator parameter is selected 5 Wire feed unit drive current input ind...

Страница 51: ...he Welding chapter under the corresponding process Welding voltage Welding voltage in V Before the start of welding the machine automatically displays a standard value based on the programmed paramete...

Страница 52: ...t filler metal lights up 25 Diameter Index wire diameter button for selecting the diameter of the wire to be used Parameter SP is reserved for additional wire diameters When a wire diameter is selecte...

Страница 53: ...also be used to display the version number of the welding database the wire feed unit number the software ver sion of the wire feed unit and the arc burning time The software version is displayed Pres...

Страница 54: ...hen the welder presses and holds the Feeder inching button see the Fdi parameter in the Setup menu 2 Parameter selection button for selecting the following parameters Sheet thickness1 Sheet thickness...

Страница 55: ...ected 7 Welding current LED lights up when the welding current parameter is selected 8 Wire feed speed LED lights up when the wire feed speed parameter is selected 9 Overtemperature indicator lights u...

Страница 56: ...u parameter EnE If the indic ator is not activated the coolant flow is displayed when the coolant device FK 4000 Rob is available If the indicators are lit up on the parameter selection button 17 and...

Страница 57: ...Gas will flow out for 30 s after pressing the gas test button Press the button again to stop the gas test flow before the end of this period Key combina tions special functions The following special...

Страница 58: ...ding database e g 0 029 M0029 Press the Material button 24 again to display the number of the wire feed unit A or B in the case of twin head mounts and the software version of the wire feed unit e g A...

Страница 59: ...ing button for feeding the wire electrode into the torch hosepack with no accompanying flow of gas or current For information on the various wire feed sequences that are possible when the welder press...

Страница 60: ...F1 indicator LED lights up when the F1 indicator parameter is selected 4 Wire feed unit drive current input indicator LED lights up when the wire feed unit drive current input indicator parameter is...

Страница 61: ...splayed Job No In the job mode process for retrieving parameter records stored under job numbers F3 indicator indicates the real energy inputs in KJ The real energy input must be activated in level 2...

Страница 62: ...lights up 23 Intermediate arc indicator a spatter prone intermediate arc occurs between the short arc and the spray arc The intermediate arc indicator lights up to alert you to this critical area 24...

Страница 63: ...ftware ver sion of the wire feed unit and the arc burning time The software version is displayed Press the Material button 24 to display the version number of the welding database e g 0 029 M0029 Pres...

Страница 64: ...Function 1 Error indicator lights up if an error has occurred The corresponding error message is dis played on all devices connected to the LocalNet that have a digital display The error messages dis...

Страница 65: ...CMT Remote and CMT Advanced control panel CMT 4000 Advanced 3 2 1 No Function 1 Error indicator lights up if an error has occurred The corresponding error message is dis played on all devices connect...

Страница 66: ...trol plug 4 Blanking cover 5 Current socket with bayonet latch for connecting the grounding earthing cable during MIG MAG welding the current connection for the TIG welding torch connecting the electr...

Страница 67: ...net latch for connecting the grounding earthing cable during MIG MAG welding the current connection for the TIG welding torch connecting the electrode cable or grounding earthing cable during MMA weld...

Страница 68: ...r the TIG welding torch connecting the electrode cable or grounding earthing cable during MMA welding depending on the type of electrode used 2 Mains switch for switching the power source on and off 3...

Страница 69: ...on the power source 9 Current socket with bayonet latch for connecting the current cable from the interconnecting hosepack during MIG MAG welding connecting the grounding earthing cable during TIG wel...

Страница 70: ...ode cable or grounding earthing cable during MMA welding depending on the type of electrode used 4 Blanking cover Reserved for LocalNet connection 5 Blanking cover Reserved for LocalNet connection 6 L...

Страница 71: ...Installation and commissioning 71 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 72: ...72 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 73: ...upply Wire feed unit TS 4000 5000 TPS 3200 4000 5000 only Interconnecting hosepack TS 4000 5000 TPS 3200 4000 5000 only Wire electrode MIG MAG auto mated welding Power source TS 4000 5000 TPS 3200 400...

Страница 74: ...power source RCU 5000i remote control Robot interface or field bus connection Grounding earthing cable CMT welding torch incl CMT drive unit Cooling unit CMT wire feed unit CMT interconnecting hosepa...

Страница 75: ...m 0 49 in protection against direct sprays of water at any angle up to 60 from the vertical The device can be set up and operated outdoors in accordance with IP23 Avoid direct wetting e g from rain WA...

Страница 76: ...wer supply The technical data shown on the rating plate applies Applies to TIME 5000 Digital power source The standard mains plug allows the user to operate with a mains voltage of up to 400 V For mai...

Страница 77: ...rican Wire Gauge Safety WARNING Danger due to work that has been carried out incorrectly This can result in serious injury and damage to property The work described below must only be carried out by t...

Страница 78: ...ut size 30 on the strain relief device PE W1 V1 U1 5 7 8 6 5 Insert the mains cable into the strain relief device NOTE Push the mains cable in far enough to make it possible to connect the ground cond...

Страница 79: ...the holding plate NOTE To ensure a reliable earth connection to the housing of the power source the points on the hexagon nut must be facing the holding plate 6 Screw the front of the large strain re...

Страница 80: ...for the following applications and situ ations TS 4000 5000 TPS 3200 4000 5000 power sources JobMaster welding torch Push pull welding torch Robot welding Hosepacks over 5 m long MIG MAG pulse synergi...

Страница 81: ...ing is composed of the following sections Commissioning the TPS 2700 Commissioning the TS 4000 5000 TPS 3200 4000 5000 Commissioning the CMT 4000 Advanced 81 EN Toowoomba Welding Supplies tweld com au...

Страница 82: ...lin ders to prevent them from falling over Observe the safety rules of the gas cylinder manufacturer Connecting the gas hose to the TPS 2700 1 Place the gas cylinder on a solid level surface in such a...

Страница 83: ...o the TPS 2700 1 Check that the torch is correctly and completely tooled up Insert it infeed tube first into the torch connection 2 Tighten the union nut by hand to fix the torch in place 3 Plug the c...

Страница 84: ...in the spare parts lists US devices are supplied without feed rollers After inserting the wirespool insert the feed rollers 4 5 3 2 1 2 1 2 3 1 2 3 Inserting the wirespool CAUTION Risk of injury from...

Страница 85: ...ry from falling wirespool Make sure the wirespool sits securely on the spool holder NOTE When working with basket type spools only use the basket type spool adapter supplied with the device CAUTION Ri...

Страница 86: ...the wire springing back CAUTION Risk of damage to the welding torch from sharp end of wire electrode Deburr the end of the wire electrode well before feeding in 4 4 1 2 1 1 2 2 2 2 3 3 1 3 1 5 2 3 4...

Страница 87: ...res that the wire is transported properly Contact pressure stand ard values Semi cylindrical rolls Trapeze rolls Plastic rolls Aluminium 1 5 3 5 4 5 Steel 3 4 1 5 CrNi 3 4 1 5 Adjusting the brake NOTE...

Страница 88: ...k of injury and damage from falling wirespool To ensure that the wirespool is properly in place and that the brake works properly fit the brake according to the following diagram 1 2 PVC 1 4 3 PVC KLE...

Страница 89: ...erence to a manual water cooled MIG MAG application Fitting the sys tem components overview The diagram below is intended to show you how to fit the individual system components For detailed informati...

Страница 90: ...2 m 4 ft interconnect ing hosepacks 2 1 Fitting the strain relief device to the wire feed unit 3 Introduce the pin on the wire feed unit strain relief device for the intercon necting hosepack into the...

Страница 91: ...ey remain stable Secure gas cylin ders to prevent them from falling over Observe the safety rules of the gas cylinder manufacturer 3 1 2 2 4 5 5 Fixing the gas cylinder on the trolley 1 Place the gas...

Страница 92: ...to fix the torch in place 3 Plug the control plug of the welding torch into the torch control connection and latch it in place NOTE When altering the length and or cross section of the welding torch...

Страница 93: ...tem components 1 3 1 2 3 Installing the wire feed unit and setting up the gas cylinder 2 1 Fasten the cooling unit and power source to the back of the machine as well using 2 screws in each case 2 Cyl...

Страница 94: ...n to the robot control Preparing the wire feed unit Carry out the following steps in accordance with the wire feed unit operating instructions 1 Insert the feed rollers in the wire feed unit 2 Insert...

Страница 95: ...Welding 95 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 96: ...96 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 97: ...s the torch trigger Hold the torch trigger Release the torch trigger GPr Gas pre flow time I S Starting current phase the base material is heated up rapidly despite the high thermal dissipation that o...

Страница 98: ...GPo 2 step mode is suitable for Tacking work Short weld seams Automated and robot welding 4 step mode t I I GPr GPo 4 step mode is suitable for longer weld seams 98 Toowoomba Welding Supplies tweld co...

Страница 99: ...Spot welding mode is suitable for welding joins on overlapped sheets Procedure for spot welding 1 Hold welding torch in the vertical 2 Press and release the torch trigger 3 Keep the torch in the same...

Страница 100: ...the power source is unplugged from the mains General tasks before MIG MAG welding 1 Only where a cooling unit and water cooled welding torch are used TPS 2700 with water cooling Plug the water hoses...

Страница 101: ...source 4 Press the Mode button to select the desired MIG MAG mode 2 step mode 4 step mode Special 4 step mode aluminium welding start up Spot welding See the Setup menu for details of how to set the p...

Страница 102: ...electric shock and from the wire electrode emerging from the torch When pressing the torch trigger keep the torch away from your face and body do not point the welding torch at people make sure that...

Страница 103: ...ter selection button to select the parameter you wish to correct 2 Use the adjusting dial to set the selected parameter to the desired value The para meter value is displayed in the digital display lo...

Страница 104: ...in 19 69 ipm maximum wire feed speed e g 22 0 m min 866 14 ipm Welding voltage TPS 3200 4000 5000 10 0 40 0 V TPS 2700 10 0 34 0 V Dynamic correction for influencing the short circuiting dynamic at th...

Страница 105: ...ding torch remain stored until the next time they are changed This is true even if the power source is switched off and on again in the meantime To display the actual welding current during welding pr...

Страница 106: ...parameters gas pre flow time gas post flow time and feeder creep speed are described in the Setup menu Adjusting para meters for cor rection 1 Press the Parameter selection button to select the parame...

Страница 107: ...lding 1 ER 70 S 3 6 Steel 3 ER 308 CrNi 19 9 5 ER 4043 AlSi 5 6 ER CuSi A CuSi 3 8 SP 1 1 10 Steel ER 70 S 3 6 12 CrNi 19 9 ER 308 14 AlSi 5 ER 4043 15 CuSi 3 ER CuSi A 16 SP 2 1 To weld the other fil...

Страница 108: ...ters are immediately adjusted to match All welding parameter set values that have been set using the adjusting dial or but tons on the welding torch remain stored until the next time they are changed...

Страница 109: ...ler metals CrNi 19 9 Ar 2 5 CO2 1 2 mm CuSi 3 100 Ar 0 8 mm CuSi 3 100 Ar 1 0 mm CuSi 3 100 Ar 1 2 mm Dynamic correction for influencing the short circuiting dynamic at the instant of droplet transfer...

Страница 110: ...m 2 CuAl 8 100 Ar 1 0 mm 2 CuSi 3 100 Ar 1 0 mm 2 Notes 1 Different ignition process from the CMT 0875 characteristic 2 Combination of CMT characteristic and pulse characteristic 3 CMT pulse character...

Страница 111: ...d by ignition If no current starts flowing before the length of wire specified in the Setup menu has been fed the power source cuts out automatically The service code no IGn appears on the control pan...

Страница 112: ...wo operating points result from the welding output being changed positively and negatively by an adjustable dFd value that can be set in the Setup menu welding power offset 0 0 2 0 m min or 0 0 78 74...

Страница 113: ...n Special 4 step mode I S Starting current phase SL Slope I E End crater phase v Wire feed speed I vD Al 2 L S L S dFd 1 F v I S dFd t I E SynchroPulse function 113 EN Toowoomba Welding Supplies tweld...

Страница 114: ...elected More information about robot welding can be found in the operating instructions for the robot interface or field bus systems and in the Robot interface leaflet 42 0410 0616 Special 2 step mode...

Страница 115: ...ectified 1 Cut off the end of the wire electrode that is sticking NOTE The error message Err 054 does not need to be acknowledged The power source is now ready for operation NOTE The standard factory...

Страница 116: ...ged from the mains Prerequisite The TIG welding process is only possible with the Comfort US and TIME 5000 Digital control panels with a TIG gas valve torch The inputs required for TIG welding are des...

Страница 117: ...tton The LED indicator on the button must light up 4 Use the adjusting dial to set the desired amperage The amperage value is shown in the left hand digital display All welding parameter set values th...

Страница 118: ...ional TIG Comfort Stop At the end of the welding operation the welding current is switched off automatically if the length of the arc increases by more than a defined amount This prevents the arc bein...

Страница 119: ...tion is triggered Keeping the torch at the same height and then removing it 4 Keep the torch in the same position The welding current is continu ously decreased downslope The arc goes out NOTE The dow...

Страница 120: ...I Preset welding current SL Downslope I t I SL TIG welding process with the optional TIG Comfort Stop function activated 120 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 121: ...from the mains Prerequisite Manual metal arc MMA welding is only possible in conjunction with the Comfort US TIME 5000 Digital and CMT control panels The inputs required for MMA welding are described...

Страница 122: ...on must light up 4 Use the adjusting dial to set the desired amperage The amperage value is shown in the left hand digital display All welding parameter set values that have been set using the adjusti...

Страница 123: ...xample of Hotstart function Legend Hti Hot current time 0 2 s factory setting 0 5 s HCU Hot start current 0 200 factory setting 150 lH Main current set welding current Function during the specified ho...

Страница 124: ...y activating the anti stick function If the rod electrode begins to stick the power source immediately switches the welding current off After the rod electrode has been detached from the workpiece the...

Страница 125: ...c welding process is automatically selected No other process can be selected on the power source Job mode dis plays on the left hand digital dis play The following job mode displays are used on the le...

Страница 126: ...e comes with no jobs pre programmed To create a job proceed as follows 1 Set the desired welding parameters that you want to store as a Job 2 Briefly press the Store button to change to the job menu T...

Страница 127: ...TE The parameters from the Setup menu are also stored for each job with the exception of the following functions Push pull unit Cooling unit switch off Measuring the welding circuit resistance Measuri...

Страница 128: ...Start welding Welding takes place with the welding parameters stored in the job During welding you can switch to another job without stopping e g in robot opera tion When you change to another process...

Страница 129: ...lease the Store button 6 Briefly press the Store button to exit from the Job menu The power source switches to the setting selected before the job was copied Deleting a job NOTE Jobs are deleted in th...

Страница 130: ...n the left hand digital display to indicate that the job has been deleted 4 Release the wire diameter button DEL 5 Briefly press the Store button to exit from the Job menu The power source switches to...

Страница 131: ...Setup settings 131 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 132: ...132 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 133: ...e Job parameter is used to select the job for which the parameters are to be adjusted The job correction menu can also be opened using the following RCU 4000 remote control Win RCU JobExplorer softwar...

Страница 134: ...ng range 0 99 numbers of the programmed jobs n memory location vacant Factory setting P Power correction correction of the welding power as defined by the wire feed speed Unit m min ipm Setting range...

Страница 135: ...om the welding program database will be used If Fdc values are set manually and these values are faster than the wire feed speed that was set for the welding operation then the feeder creep speed is e...

Страница 136: ...ry setting 1 0 F Frequency for SynchroPulse option Unit Hz Setting range OFF or 0 5 5 Factory setting OFF dFd delta Feeder Welding power offset for the SynchroPulse option defined by the wire feed spe...

Страница 137: ...remain saved After the power source has been switched on again the parameters are reset to the permanently settable values Minimum and maximum are used for setting ranges that differ according to pow...

Страница 138: ...for AL c JSL Job Slope defines the time between the job that is currently selected and the next job Unit s Setting range OFF or 0 1 9 9 Factory setting OFF Job t s Job 1 Job 2 Job 1 JSL OFF Job 1 JSL...

Страница 139: ...ME 5000 Digital and CMT control panels Protective gas shield setup menu Overview Opening the Protective gas shield setup menu 1 Press and hold the Store button 2 Press the Gas test button 3 Release th...

Страница 140: ...d until a new GPU value is entered NOTE Purging the shielding gas is necessary if condensation forms when the device is left unused in a cold environment for a prolonged period Long hosepacks are most...

Страница 141: ...ters in the Setup menu for the Standard con trol panel NOTE The number of parameters available for the Standard control panel and the order in which they are arranged is not the same as in the extende...

Страница 142: ...to one second Irrespective of the value that has been set the wire feed speed remains at 1 m min or 39 37 ipm for the first second Hold the button for up to 2 5 seconds After one second the wire feed...

Страница 143: ...set NOTE When the power source is reset all the customised settings in the Setup menu are lost When the power source is reset jobs are not deleted but are retained in the memory The functions in the s...

Страница 144: ...ergic weld ing process 2 Press and hold the Store button 3 Press the Process button 4 Release the Store button The power source is now in the setup menu for the MIG MAG standard syn ergic welding proc...

Страница 145: ...37 max Factory setting 10 393 7 NOTE To facilitate the exact positioning of the wire electrode the following sequences are possible when the welder presses and holds the Feeder inching button down t...

Страница 146: ...ed in more detail in the MIG MAG welding section dFd delta Feeder Welding power offset for the SynchroPulse option defined by the wire feed speed Unit m min ipm Setting range 0 0 2 0 0 0 78 74 Factory...

Страница 147: ...When the power source is reset jobs are not deleted but are retained in the memory The functions in the second level of the Setup menu 2nd are also not deleted Excep tion Ignition time out welding pa...

Страница 148: ...Factory setting 150 2nd Second level of the Setup menu see Setup menu level 2 148 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 149: ...G standard synergic welding or MIG MAG pulse synergic welding 2 Use the Mode button to select Spe cial 4 step mode 3 Press and hold the Store button 4 Press the Mode button 5 Release the Store button...

Страница 150: ...1 9 9 Factory setting OFF In the MIG MAG welding section the parameters for Special 2 step mode for robot inter face are illustrated by means of a diagram Welding paramet ers for Special 4 step mode...

Страница 151: ...Parameters for spot welding in the Mode setup menu SPt Spot welding time Unit s Setting range 0 1 5 0 Factory setting 1 0 151 EN Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 152: ...evel 2 for the Standard control panel Changing to the second menu level 2nd 1 Access the Setup menu for the Standard control panel 2 Select 2nd welding parameter 3 Press and hold the Store button 4 Pr...

Страница 153: ...Press the Store button The power source is now in the Pro cess setup menu 9 To exit from the Process setup menu press the Store button again Parameters for MIG MAG welding in the Setup menu level 2 PP...

Страница 154: ...ire stick function Stc are available when a robot interface or field bus coupler for robot control is connected to the LocalNet The wire stick control function Stc is described in the Robot welding se...

Страница 155: ...only transmitted to the robot control via the field bus NOTE The noE setting only functions in conjunction with the field bus applications Robot interfaces ROB 4000 5000 do not support this function...

Страница 156: ...to the welding speed Unit kJ Setting range ON OFF Factory setting OFF Since the full range of values 1 kJ 99999 kJ cannot be displayed on the three digit display the following display format has been...

Страница 157: ...g unit cuts out after a 2 minute welding off time NOTE If the FK 4000 thermostat option has been installed in the cooling unit the cool ing unit cuts out as soon as the return temperature has dropped...

Страница 158: ...of the arc r r resistance Welding circuit resistance in mW see Measuring welding circuit resistance r L L inductivity Welding circuit inductivity in microhenry see Displaying welding circuit inductiv...

Страница 159: ...age This results in a vertical characteristic 4 The con parameter is especially suitable for rutile electrodes and basic electrodes as well as for gouging For arc air gouging set the arc force dynamic...

Страница 160: ...given arc length to the load line 1 Depending on what welding current I has been set the point of intersection operating point of characteristics 4 5 and 6 will be displaced along the load line 1 The...

Страница 161: ...iece With the Uco parameter the welding voltage can be limited to a value that makes it possible to end the welding operation simply by slightly lifting the rod electrode If the welding process is sto...

Страница 162: ...2nd 3 Press and hold the Store button Press the Process button Release the Store button 4 Select the PPU function 5 Use the adjusting dial to select the corresponding push pull unit 6 Press the Feeder...

Страница 163: ...8 1 x 2 Fronius robot push pull KD Drive 10 m min 393 70 ipm 1 x x 3 Fronius robot push pull Robacta Drive Master control 1 Use with long torch hosepacks of 3 5 8 m 11 ft 5 80 in 26 ft 2 96 in in conj...

Страница 164: ...x 50 Fronius manual push pull PT Drive d 0 8 mm 0 030 in material aluminium 3 x 51 Fronius manual push pull PT Drive d 1 0 mm 0 040 in material aluminium 3 x 52 Fronius manual push pull PT Drive d 1...

Страница 165: ...utton or the torch trigger The wire feed unit motors are calibrated while not under load During the calibration process run is displayed on the right hand digital display Once the calibration in the u...

Страница 166: ...ot need to be calibrated while under load St2 the previ ously set values e g PPU and 5 will appear on the digital display when you press the Feeder inching button or torch trigger Calibration of the p...

Страница 167: ...nal speed value Repeat the push pull calibration If the error message re appears Contact After Sales Service Cause Remedy St1 E 3 At minimum wire feed speed the wire feed unit motor does not deliver a...

Страница 168: ...the inner liner for kinks or soiling check the contact pressure on the 2 roller or 4 roller drive of the push pull unit Repeat the push pull calibration If the error message re appears Con tact After...

Страница 169: ...2 E 15 At maximum wire feed speed the motor current of the push pull unit is out side the permitted range Possible reasons are disengaged wire feed unit motors or wire feed problems Engage the drive u...

Страница 170: ...hosepack NOTE The welding circuit resistance r depends on the hosepack used if the hosepack length or cross sectional area is changed measure the welding cir cuit resistance r again measure the weldi...

Страница 171: ...During the measurement run is dis played on the right hand digital display The measurement is finished when the welding circuit resistance is shown on the right hand digital display e g 11 4 mW 8 Fit...

Страница 172: ...Where very high welding circuit inductivity occurs it is also possible to attempt to influ ence the welding results with the droplet detachment correction parameter If this does not produce the desir...

Страница 173: ...Troubleshooting and maintenance 173 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 174: ...174 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 175: ...onnection Displayed service codes If any error message that is not described here appears on the displays then the fault can only be fixed by a service technician Make a note of the error message show...

Страница 176: ...nt in wire feed unit drive Arrange the hosepack in as straight a line as possible check that there are no kinks or dirt in the inner liner check the contact pressure on the 2 roller or 4 roller drive...

Страница 177: ...rotational speed from the push pull unit motor Check the actual value pick up and the cable connections to and from it and replace if necessary Cause Remedy EFd 15 1 Wire buffer empty Counter lever on...

Страница 178: ...o wire buffer missing Check connection to wire buffer check wire buffer control line Cause Remedy EFd 30 1 LHSB connection to power source missing Check LHSB connection to power source Cause Remedy EF...

Страница 179: ...n filter or replace acknowledge Err 056 by pressing the Store button Excessive ambient temperature on the VR 1500 11 12 30 Reduce ambient temperature if necessary position and operate welding machine...

Страница 180: ...ause Remedy Err Cfg Can only occur when power sources are being operated in parallel or in Twin mode Power source is configured for parallel operation setup parameter P C is set to ON or TimeTwin Digi...

Страница 181: ...triggered Cause Remedy no H2O Cooling unit flow watchdog has been triggered Check the cooling unit top up with coolant or bleed the water flow if neces sary see cooling unit operating instructions The...

Страница 182: ...r source Allow power source to cool down Cause Remedy tP3 xxx Note xxx is a temperature value Overtemperature in the primary circuit of the power source Allow power source to cool down Cause Remedy tP...

Страница 183: ...uit Allow power source to cool down Cause Remedy Power source does not function Mains switch is on but indicators are not lit up There is a break in the mains lead the mains plug is not plugged in Che...

Страница 184: ...ice Cause Remedy Cause Remedy Cause Remedy Cause Remedy No welding current Mains switch is ON and indicators are lit up Grounding earthing connection is incorrect Check the grounding earthing connecti...

Страница 185: ...ground earth connection Ensure good contact to workpiece Inadequate or no protective gas shield Check the pressure regulator gas hose gas solenoid valve torch gas con nection etc Welding torch is lea...

Страница 186: ...medy Cause Remedy Cause Remedy Cause Remedy Cause Remedy Wirefeed problems when using long hosepacks Incorrect arrangement of hosepack Arrange the hosepack in as straight a line as possible avoid tigh...

Страница 187: ...ry start up Check mains plug mains cable welding torch interconnecting hosepack and grounding earthing connection for damage Check whether the all round clearance of 0 5 m 1 ft 8 in is kept to ensure...

Страница 188: ...188 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 189: ...Appendix 189 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 190: ...190 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 191: ...ax at PCC 2 95 mOhm Primary continuous current 100 d c 3 6 6 A Primary continuous power 4 5 8 7 kVA Cos phi 0 99 Efficiency 87 Welding current range MIG MAG 3 270 A Rod electrode 10 270 A TIG 3 270 A...

Страница 192: ...t 230 400 V and 50 Hz 2 PCC Interface to the public grid 3 d c Duty cycle TPS 2700 MV Mains voltage 3 x 200 240 V 3 x 380 460 V Mains voltage tolerance 10 Mains frequency 50 60 Hz Mains fuse protectio...

Страница 193: ...Max permitted wirespool weight 16 kg 35 27 lb Wirespool diameter 300 mm 11 81 in Wire diameter 0 8 1 6 mm 0 03 0 06 in Drive 4 roller drive Maximum shielding gas pressure 7 bar 101 psi The wire feed u...

Страница 194: ...class F EMC emission class A Marks of conformity CE Safety symbol S Dimensions l x w x h 626 x 287 x 477 mm 24 65 x 11 30 x 18 78 in Weight 34 6 kg 76 3 lb 1 connected to public grid at 230 400 V and...

Страница 195: ...lass A Marks of conformity CE CSA Safety symbol S Dimensions l x w x h 626 x 287 x 477 mm 24 65 x 11 30 x 18 78 in Weight 34 6 kg 76 3 lb 1 connected to public grid at 230 400 V and 50 Hz 2 d c Duty c...

Страница 196: ...ge 320 A 49 1 63 1 V Open circuit voltage 64 67 V Degree of protection IP 23 Type of cooling AF Insulation class F EMC emission class A Marks of conformity CE CSA Safety symbol S Dimensions l x w x h...

Страница 197: ...cooling AF Insulation class F EMC emission class A Marks of conformity CE CSA Safety symbol S Dimensions l x w x h 626 x 287 x 477 mm 24 65 x 11 30 x 18 78 in Weight 35 2 kg 77 6 lb 1 connected to pu...

Страница 198: ...sion class A Marks of conformity CE CSA Safety symbol S Dimensions l x w x h 626 x 287 x 477 mm 24 65 x 11 30 x 18 78 in Weight 35 2 kg 77 6 lb 1 connected to public grid at 230 400 V and 50 Hz 2 d c...

Страница 199: ...287 x 477 mm 24 65 x 11 30 x 18 78 in Weight 35 6 kg 78 5 lb 1 connected to public grid at 230 400 V and 50 Hz 2 d c Duty cycle TS TPS 5000 MV Mains voltage 3 x 200 240 V 3 x 380 460 V Mains voltage t...

Страница 200: ...230 400 V and 50 Hz 2 d c Duty cycle Technical data US devices See TPS 2700 MV 3200 MV and TS TPS 4000 MV 5000 MV Technical data Alu edition CrNi edition Yard edi tion and CMT variants The technical...

Страница 201: ...n class F EMC emission class A Marks of conformity CE Safety symbol S Dimensions l x w x h 626 x 287 x 477 mm 24 65 x 11 30 x 18 78 in Weight 37 4 kg 82 45 lb 1 connected to public grid at 230 400 V a...

Страница 202: ...w x h 625 x 290 x 705 mm 24 61 x 11 42 x 27 76 in Weight 54 2 kg 119 49 lb 1 connected to public grid at 230 400 V and 50 Hz 2 d c Duty cycle CMT 4000 Advanced MV Mains voltage 3 x 200 240 V 3 x 380 4...

Страница 203: ...it voltage 90 V Degree of protection IP 23 Type of cooling AF Insulation class F EMC emission class A Marks of conformity CE CSA Safety symbol S Dimensions l x w x h 625 x 290 x 705 mm 24 61 x 11 42 x...

Страница 204: ...R308 Ar 97 5 CO2 2 5 AlMg 5 ER5356 Ar 100 AlSi 5 ER4043 Ar 100 CuSi 3 ER CuSi A Ar 100 SP2 P 0074 S 0008 P 0346 S 1084 P 0378 S 0375 P 0148 S 0149 P 0421 S 0102 P 0345 S 0033 P 0076 S 0009 C P 0959 P...

Страница 205: ...t out In position Aut the cut out is automatic depending on the coolant temperature In position On Off the cooling unit remains permanently switched on switched off Separate adjustment for the MIG MAG...

Страница 206: ...em FCO Feeder control Wire feed unit cut out wire end sensor option Fdc Feeder creep Feeder creep speed Fdi Feeder inching Feeder inching speed Terms and abbre viations G I GAS Gasflow Set value for s...

Страница 207: ...boundary high for the welding power job correction PcL Power correction Low Correction boundary low for the welding power job correction PPU Push pull unit r r resistance Determine welding circuit res...

Страница 208: ...urrent duration t S time Starting current Starting current duration tri Trigger Subsequent correction of the mode Uco U Voltage cut off Welding voltage limitation during MMA welding Makes it possible...

Страница 209: ...209 EN Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 210: ...210 Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 211: ...211 EN Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Страница 212: ...Toowoomba Welding Supplies tweld com au Ph 61 7 4659 0044...

Отзывы: