Safety Measures
in Normal Opera-
tion
Use instructions and checks within the company to ensure that the vicinity of
the workplace is always clean and organized.
Only set up and operate the device in accordance with the degree of protec-
tion shown on the rating plate.
Install the device with an all-round clearance of at least 0.5 m (19.69 in.) to
walls, neighboring devices, or other objects.
Install the device at a minimum distance of 1 m (40 in.) away from IT equip-
ment and control lines, as well as from the welding process.
Set up the device in such a way that welding spatter cannot hit the cleaning
device.
Before transporting the device, always completely drain the parting agent.
Take care to ensure that the applicable national and regional guidelines and
accident prevention regulations are observed when transporting the device,
especially guidelines concerning hazards during transport and shipment.
It is essential to conduct a visual inspection of the device to check for damage
after it has been transported but before it is commissioned. Have any damage
repaired by trained service technicians before commissioning the device.
Only operate the device when all safety devices are fully functional. If the safe-
ty devices are not fully functional, there is a danger of:
-
Injury or death to the operator or a third party
-
Damage to the device and other material assets belonging to the operat-
ing company
-
Inefficient operation of the device
Safety devices that are not fully functional must be repaired before the device
is started up.
Never bypass or disable safety devices.
Before starting up the device, ensure that no one can be put in danger.
The device must be examined at least once a week for externally detectable
damage and functionality of the safety devices.
-
Only use appropriate original parting agents from the manufacturer.
-
When handling parting agents, observe the information on the parting
agent safety data sheets. The parting agent safety data sheets can be ob-
tained from your service center or via the manufacturer’s website.
-
Do not mix parting agents from the manufacturer with other parting
agents.
-
If damage occurs due to the use of other parting agents, the manufacture
is not liable for this and all warranty claims are forfeited.
-
Properly dispose of used parting agents according to national and inter-
national regulations.
Содержание Cleaning Unit TC 2000
Страница 2: ...2...
Страница 4: ...4...
Страница 15: ...General...
Страница 16: ......
Страница 24: ...24...
Страница 25: ...Operating controls connections and mechanical components...
Страница 26: ......
Страница 34: ...34...
Страница 35: ...Installation and Startup...
Страница 36: ......
Страница 43: ...43 EN US 4 Tightening torque 1 3 Nm 5 Tightening torque 0 5 Nm 6 4 1 5 1 2 3 4 6...
Страница 52: ...52...
Страница 53: ...Troubleshooting Maintenance and Disposal...
Страница 54: ......
Страница 61: ...Technical Data...
Страница 62: ......
Страница 65: ...65 EN US...
Страница 66: ...66...
Страница 67: ...67 EN US...