![Fronius Acerios Скачать руководство пользователя страница 73](http://html1.mh-extra.com/html/fronius/acerios/acerios_operating-instructions-manual_2339066073.webp)
tSt | xxx
Note: xxx stands for a temperature value
Overtemperature in the control circuit of the power source
Leave power source to cool
Cause:
Remedy:
Err | 049
Phase error in the power supply
Check the mains fuse, the grid lead and the mains plug
Cause:
Remedy:
Err | 050
Indirect symmetry error
Contact After-Sales Service
Cause:
Remedy:
Err | 051
Mains undervoltage: Mains voltage has fallen below the tolerance
range (see "Technical Data" section)
Check the mains voltage
Cause:
Remedy:
Err | 052
Mains overvoltage: Mains voltage has exceeded the tolerance range
(see "Technical Data" section)
Check the mains voltage
Cause:
Remedy:
no | IGn
The ignition time-out function is active; current did not start flowing
within the time specified in the Setup menu. The power source safety
cut-out has tripped
Check the plasma torch wearing parts; if necessary, increase the
period of time in the "2nd Level Setup Menu" to the safety cut-out
Cause:
Remedy:
Err | PE
The earth current watchdog has triggered the safety cut-out of the
power source.
Switch off the power source, wait for 10 seconds and then switch it
back on again; if the error occurs again despite numerous attempts to
eliminate it - contact After-Sales Service
Cause:
Remedy:
Err | IP
Primary overcurrent
Contact After-Sales Service
Cause:
Remedy:
Err | bPS
Power module error
Contact After-Sales Service
Cause:
Remedy:
dSP | Axx
Error in the central control and regulation unit
Contact After-Sales Service
Cause:
Remedy:
dSP | Cxx
Error in the central control and regulation unit
Contact After-Sales Service
Cause:
Remedy:
dSP | Exx
Error in the central control and regulation unit
Contact After-Sales Service
Cause:
Remedy:
73
EN-US
Содержание Acerios
Страница 1: ...Operating instructions Acerios 42 0426 0326 EA 003 21032022 EN US Operating instructions...
Страница 2: ......
Страница 17: ...General information 17...
Страница 18: ...18...
Страница 21: ...Operating controls and connec tions 21...
Страница 22: ...22...
Страница 30: ...30...
Страница 31: ...Installation and Startup 31...
Страница 32: ...32...
Страница 38: ...38...
Страница 39: ...Plasma Surface Treatment 39...
Страница 40: ...40...
Страница 53: ...Setup Settings 53...
Страница 54: ...54...
Страница 68: ...68...
Страница 69: ...Troubleshooting and Maintenance 69...
Страница 70: ...70...
Страница 79: ...Appendix 79...
Страница 80: ...80...
Страница 82: ...82...
Страница 83: ...83 EN US...