Fronius 63A-3 Скачать руководство пользователя страница 5

For the location of the safety and danger notices on the device, refer to the section
headed "General remarks" in the Operating Instructions for the device.

Any equipment malfunctions which might impair safety must be remedied before the
device is turned on.

This is for your personal safety!

Environmental
conditions

Operation or storage of the device outside the stipulated area will be deemed as not in
accordance with the intended purpose. The manufacturer accepts no liability for any
damage resulting from improper use.

Qualified person-
nel

The servicing information contained in these operating instructions is intended only for
the use of qualified service engineers. An electric shock can be fatal. Do not carry out
any actions other than those described in the documentation. This also applies to quali-
fied personnel.

All cables and leads must be secured, undamaged, insulated and adequately dimen-
sioned. Loose connections, scorched, damaged or inadequately dimensioned cables and
leads must be immediately repaired by authorised personnel.

Maintenance and repair work must only be carried out by an authorised specialist.

It is impossible to guarantee that bought-in parts are designed and manufactured to meet
the demands made on them, or that they satisfy safety requirements. Use only original
spare parts (also applies to standard parts).

Do not carry out any alterations, installations, or modifications to the device without first
obtaining the manufacturer's permission.

Components that are not in perfect condition must be changed immediately.

Copyright

Copyright of these operating instructions remains with the manufacturer.

The text and illustrations are all technically correct at the time of printing. We reserve the
right to make changes. The contents of the operating instructions shall not provide the
basis for any claims whatsoever on the part of the purchaser. If you have any sugges-
tions for improvement, or can point out any mistakes that you have found in the instruc-
tions, we will be most grateful for your comments.

Data protection

The user is responsible for the safekeeping of any changes made to the factory settings.
The manufacturer accepts no liability for any deleted personal settings.

5

EN

Содержание 63A-3

Страница 1: ...ourced from certified sustainable forests FSC Perfect Charging Perfect Welding Solar Energy Fronius Smart Meter 63A 3 EN Operating instructions System monitoring 42 0426 0293 EN 007 04032021 www youtu...

Страница 2: ......

Страница 3: ...s Fronius SnapInverter 13 Multi meter system Fronius SnapINverter 14 Modbus participants Fronius GEN24 15 Multi meter system Fronius GEN24 inverter 16 Menu structure 17 Setting the address of the Fron...

Страница 4: ...nowledge of and experience in dealing with electrical installations and Have fully read and precisely followed these Operating Instructions The Operating Instructions must always be at hand wherever t...

Страница 5: ...y repaired by authorised personnel Maintenance and repair work must only be carried out by an authorised specialist It is impossible to guarantee that bought in parts are designed and manufactured to...

Страница 6: ...that could result in serious injury and damage to property Symbols on the rating plate CE mark The devices conform to all the requisite and relevant standards and guidelines that form part of the rele...

Страница 7: ...Placement at the feed in point Fronius Smart Meter located at the feed in point Placement at the consumption point Fronius Smart Meter located at the consumption load 7 EN...

Страница 8: ...ress see Setting the address under Setting the address of the Fronius Smart Meter on page 17 11 Configure and commission the meter see Start up on page 19 Installation The Fronius Smart Meter can be m...

Страница 9: ...ax 10 mm Recommended torque 1 2 Nm max 1 4 Nm Data communication and neutral conductor connection cross section Wire rigid min 0 05 mm max 4 mm Wire flexible min 0 05 mm max 2 5 mm Recommended torque...

Страница 10: ...sful commissioning Note the following information about connecting the data communication cable to the inverter Use cables of type CAT5 or higher Use a mutual twisted cable pair for data lines that be...

Страница 11: ...Terminating resistor R 120 Ohm is included in the scope of supply Modbus RTU slave e g Fronius Ohmpilot Fronius Solar Battery etc Terminating resistor R 120 Ohm Terminating res istors Due to interfere...

Страница 12: ...ted by the PV modules or supplied by the battery Inverter in the system e g Fronius Primo Fronius Symo etc Utility meter Measures the measurement data relevant for billing amounts of energy in particu...

Страница 13: ...er plant in the consumption branch and provides measurement data for energy pro filing in Fronius Solar web Modbus RTU slave e g Fronius Ohmpilot Fronius Solar Battery etc Loads in the system e g wash...

Страница 14: ...r on page 17 The primary meter is always assigned address 1 All the other meters are numbered consecutively with the address range from 2 to 14 Different Fronius Smart Meter power categories can be us...

Страница 15: ...nius GEN24 The inputs M0 and M1 can be selected for this purpose A maximum of 4 Modbus parti cipants can be connected to the Modbus terminal on inputs M0 and M1 IMPORTANT Only one primary meter one ba...

Страница 16: ...Smart Meter on page 17 The primary meter is always assigned address 1 All the other meters are numbered consecutively with the address range from 2 to 14 Different Fronius Smart Meter power categorie...

Страница 17: ...el Menu structure A graphic view of the menu structure can be found in the User Information that is sup plied as standard Setting the address of the Fronius Smart Meter Symbol Name Event Function Prog...

Страница 18: ...18...

Страница 19: ...Start up 19...

Страница 20: ...20...

Страница 21: ...ius Datamanager start page is displayed LAN 1 Connect the Fronius Datamanager and computer to a LAN cable 2 Place the Fronius Datamanager IP switch in the A position 3 In the browser address bar enter...

Страница 22: ...IP address for LAN 169 254 0 180 or the host and domain name of the Fronius Datamanager and confirm The Fronius Datamanager website will be displayed 2 Click the Settings button 3 Log in to the login...

Страница 23: ...e connection to the inverter in the network settings the inverter is dis played with the name FRONIUS_PILOT and the serial number of the device 3 Password enter 12345678 and confirm IMPORTANT To enter...

Страница 24: ...Position drop down list set the position of the meter feed in point or con sumption point For more information on the position of the Fronius Smart Meter see Positioning on page 6 7 Click the Add but...

Страница 25: ...Operating range EN IEC 62053 21 EN IEC 62053 23 Active cos 0 5 ind to 0 8 cap Reactive sen 0 5 ind to 0 5 cap Current distortion factor in acc with EN 50470 Output Energy pulse Optical relay with NO...

Страница 26: ...loss for thermal dimensioning of the switch cabinet 6 W Mechanical environment Electromechanical environment M1 E2 Housing Housing 4 modules according to DIN 43880 Sealable front and terminal cover Co...

Страница 27: ...ailed country specific warranty terms are available on the internet www fronius com solar warranty To obtain the full warranty period for your newly installed Fronius inverter or storage sys tem pleas...

Страница 28: ...INTERNATIONAL GMBH Froniusstra e 1 A 4643 Pettenbach AUSTRIA contact fronius com www fronius com Under www fronius com contact you will find the addresses of all Fronius Sales Service Partners and lo...

Отзывы: