Status codes
Service class 1
Status codes of these class only arise momentarily and are caused by the public grid.
The initial response of the inverter in this case is to disconnect itself from the grid. The grid
is subsequently checked for the stipulated monitoring period. If no further problem has
been detected by the end of this period, then the inverter will resume feeding energy into
the grid.
Code
Description
Behaviour
Remedy
102
Grid voltage above permit-
ted limit
1. Mains voltage error
1. Check mains voltage
2. Incorrect values in the Ser-
vice Menu / Wrong Setup
2. Check values in the Service
Menu / Check Setup
3. Measuring error on the filter
board
3. Change filter board
103
Grid voltage below permit-
ted limit
1. Mains voltage error
1. Check mains voltage
2. Wrong AC cabling
2. Check AC cabling
3. Incorrect values in the Ser-
vice Menu / Wrong Setup
3. Check values in the Service
Menu / Check Setup
4. Bad contact: wall bracket <-
> filter board
4. Check AC wall bracket
screws
5. Measuring error on the filter
board
5. Change filter board
105
Mains frequency above
permitted limit
1. Mains voltage error
1. Check mains voltage
2. Incorrect values in the Ser-
vice Menu / Wrong Setup
2. Check values in the Service
Menu / Check Setup
3. Reconnection limit
3. Normal legal requirement,
no error (50,05Hz)
4. Ripple control signals
4. Report to TSI specialist
5. Measuring error on the filter
board
5. Change filter board
106
Mains frequency below per-
mitted limit
1. Mains voltage error
1. Check mains voltage
2. Incorrect values in the Ser-
vice Menu / Wrong Setup
2. Check values in the Service
Menu / Check Setup
3. Ripple control signals
3. Report to TSI specialist
4. Measuring error on the filter
board
4. Change filter board
107
Synchronisation with the
public mains supply not
possible
1. Incorrect values in the Ser-
vice Menu / Wrong Setup
1. Check values in the Service
Menu / Check Setup
2. Bad contact of the power
stage set with AC
2. Check AC connector screws
3. Bad AC connection
3. Check mains connection
4. Measuring error on the filter
board
4. Change filter board
Содержание 10.0-3 480
Страница 2: ...2 ...
Страница 5: ...Allgemeine Informationen ...
Страница 6: ......
Страница 13: ...Fehler Suchhilfe ...
Страница 14: ......
Страница 33: ...Komponenten austauschen ...
Страница 34: ......
Страница 40: ...40 Gewindebuchsen in der Grundscha le tauschen 1 2 3 4 5 1 2 3 4 5 ...
Страница 41: ...41 DE 6 6 ...
Страница 73: ...Sicherheitstechnische Überprüfung ...
Страница 74: ......
Страница 86: ...86 ...
Страница 89: ...General information ...
Страница 90: ......
Страница 97: ...Error location aid ...
Страница 98: ......
Страница 116: ...116 ...
Страница 117: ...Changing components ...
Страница 118: ......
Страница 124: ...124 Replacing thread ed bushings in the base shell 1 2 3 4 5 1 2 3 4 5 ...
Страница 125: ...125 EN 6 6 ...
Страница 156: ...156 ...
Страница 157: ...Safety Inspections ...
Страница 158: ......
Страница 170: ...170 ...
Страница 171: ...Appendix ...
Страница 176: ...176 Circuit diagrams Fronius Symo ...
Страница 177: ...177 Circuit diagrams Fronius 15 0 ...
Страница 178: ...178 ...
Страница 179: ...179 ...