P380 Pneumatic Strapping Tool Operation Manual | FPA001 | Apr 2018 | Page 4
3. OPERATION DESCRIPTION
3.1 Installation
Compressed Air Connection
The compressed air should be connected to the tool preferably by a quick coupling.
It is very important to clean the compressed air with an air unit consisting of a
separator for water and dirt, a pressure regulator with a manometer and a lubricator
(see sketch).
3.2 Suspension of Tool
It is possible to suspend the tool on a spring loaded balancer using the suspension
bracket which is supplied with the tool. The suspension bracket has been designed
in such a way, that the tool can be used for all three working positions.
Main air
line min. 2”
Air line min. 1/2”
Shut off valve
Pressure adjustment
valve with manometer
Air unit min. G1/2
Air hose
Max. length 5m
Min. Ø inside 10mm
Coupling min. G1/4
Filter with
water separator
Lubricator
(1
– 2 drops/min)
Drain of main air line
with shut off valve