5-10
Additional the screws N1.2112 have to be glued with the
idler step P35.0130 using
LOCTITE 222.
Don’t clamp the planet shaft on the pinion while loosening or
tightening the screws N1.2112.
5.4.6
Lubrication rules
All gear parts have to be lubricated with
MOLYKOTE BR 2 PLUS
grease.
Lubrication interval: While each maintenance or after 12 months at the latest.
All bearing parts of the welding unit have to be cleaned and
lubricated with
Klüber Isoflex Alltime SL2
grease while
each maintenance.
Lubrication interval: While each maintenance or after 12
months at the latest.
All other parts have to be greased due to the explosion drawing.
Lubrication interval: While each maintenance
5.4.7 Assembly informations
Pay attention to the direction of the teeths
while assembling the grippers into the
tensioning body P35.3204/P35.3205.
(look at the picture)
P35.0130
N1.2112
Clamp
here
P32.1029
N3.1702 (6X)
P32.1027
P32.1511
Bearing
welding unit
P35.3204/P35.3205
Grippers