![Froling PE1 Pellet Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/froling/pe1-pellet/pe1-pellet_installation-instructions-manual_2338712031.webp)
Description
PE1 Pellet 32
PE1 Pellet 35
Test book number
PB0770015
PB0780015
Test data - Emissions in [mg/MJ]
1)
(nominal load/partial load)
Carbon monoxide (CO)
mg/MJ
10 / 12
11 / 12
Nitrogen oxide (NOx)
mg/MJ
93 / 62
95 / 62
Organic hydrocarbons (OGC)
mg/MJ
0.5 / 0.7
0.4 / 0.7
Dust
mg/MJ
7.3 / 4.0
8.1 / 4.0
Boiler efficiency
%
94.2 / 94.7
94.3 / 94.7
1.The pollutant concentration is specified as a mass based on the energy content of the fuel fed to the combustion system in mg/MJ
Test data - Emissions in [mg/m³]
1)
(nominal load/partial load)
Carbon monoxide (CO)
mg/m³
16 / 18
17 / 18
Nitrogen oxide (NOx)
mg/m³
142 / 94
145 / 94
Organic hydrocarbons (OGC)
mg/m³
0.8 / 1.0
0.7 / 1.0
Dust
mg/m³
11.3 / 6.2
12.4 / 6.2
Boiler efficiency
%
94.2 / 94.7
94.3 / 94.7
1.Emissions values based on dry flue gas at standard temperature and pressure (0°C, 1,013 mbar) with a volume content of oxygen of 13%
Test report data
Technology
3
Technical specifications
Installation Instructions PE1 Pellet 7-35 | M1441017_en
31